Static head matters
On a system with only friction (fans, closed heating and cooling loops) the pressure needed falls with the square of flow, so power falls with the cube: at 50% flow a drive needs about 13% of full power. When part of the head is static, such as lifting water into a tank, the pump must still deliver that head at low flow, so the saving is much smaller. Enter the input power you measure now at each operating point with the present control; with bypass control the power stays near 100% whatever the flow.
Assumptions and limits
- Pump or fan efficiency unchanged at reduced speed; drive losses as entered.
- The duty profile represents a typical year.
References
- US Department of Energy, Improving Pumping System Performance: A Sourcebook for Industry, 2nd ed., 2006.
- US Department of Energy, Improving Fan System Performance: A Sourcebook for Industry, 2003.
- Karassik, I. J., Messina, J. P., Cooper, P. and Heald, C. C., Pump Handbook, 4th ed., McGraw-Hill, 2008 (affinity laws).
Questions
- What does a drive save on the example 30 kW fan?
- Over 7,000 hours at the example duty points, energy falls from 182,850 kWh to 101,234 kWh, a 45% saving of 81,615 kWh or 12,242 a year at 0.15 per kWh, so a 9,000 drive pays back in about 9 months.
- Why do savings at 50% flow look so large?
- With no static head, power at half speed is 0.5³ = 12.5% of full power, while a damper or valve at half flow typically still draws 70–80%.