The break-even ratio
A heat pump with an SCOP of 3.2 replacing a boiler that is 88% efficient costs less to run as long as electricity costs less than 3.64 times as much per kWh as the fuel. CO₂ follows the same logic with emission factors: on a grid at 0.13 kg CO₂e/kWh a heat pump emits far less than a gas boiler, while on a coal-heavy grid the advantage shrinks. SCOP depends on the climate and the flow temperature: radiators sized for low flow temperatures raise it considerably.
Assumptions and limits
- Same heat delivered by both systems; no backup heater.
- Running costs only; purchase, installation and servicing are not included.
References
- EN 14825, Air conditioners, liquid chilling packages and heat pumps — Testing and rating at part load conditions and calculation of seasonal performance.
- UK DESNZ, Greenhouse gas reporting: conversion factors 2026 (electricity).
- US EPA, GHG Emission Factors Hub, January 2025 (natural gas).
Questions
- Is a heat pump cheaper to run than a gas boiler for 12,000 kWh of heat?
- With gas at 0.07 and electricity at 0.25 per kWh, the boiler costs 955 and the heat pump (SCOP 3.2) 938, a saving of 17 a year; CO₂ falls from 2,471 kg to 491 kg on the UK 2026 grid factor.
- What SCOP do I need to break even?
- SCOP = boiler efficiency × electricity price ÷ fuel price: 0.88 × 0.25 ÷ 0.07 = 3.14 in the example.
Results depend on the figures and factors you enter and on the assumptions listed above. Use the factor set your reporting scheme requires. Read the disclaimer.