Compressed Air Leak Cost Calculator (Leak Flow and Energy Wasted)

Leaks typically waste a fifth or more of the air a compressor makes, and compressed air is one of the most expensive forms of energy on a site. This calculator estimates how much air escapes through holes of a given size at line pressure and what the compressor spends making it.

Estimates using the emission factors shown. Check the factor source and year for formal reporting.

Inputs

Results

Cost of the leaks per year
$31,698.90
Air lost (free air)
4.064
Compressor power wasted
26.42
Energy wasted per year
211,326
CO₂e per year
27,675

    RefENV-EFF-006
    MethodChoked flow: ṁ = Cd·A·p₀·√(γ/(R·T₀))·(2/(γ + 1))^((γ+1)/(2(γ−1))); power = free air flow × specific power
    Currency, unitsUSD, SI
    Date2026-11-24

    Working

    Money amounts are plain numbers shown in the currency chosen at the top of the page (symbol only; nothing is converted and no exchange rates are used). Other quantities are calculated in SI base units and converted from the units you choose.

    1. Mass flow per leak (choked)ṁ = Cd·A·p₀·√(γ/(R·T₀))·0.57870.61 × 7.069 mm² × 8.013 bar abs → 29.36 kg/h per leak
    2. Free air lostṁ ÷ ρ at 1.013 bar, 20 °C293.6 kg/h ÷ 1.204 kg/m³ = 4.064 m³/min (143.5 cfm)
    3. Compressor powerfree air × specific power4.064 m³/min × 6.5 kW per m³/min = 26.42 kW
    4. Energy and costkW × hours × price211,326 kWh × $0.15 = $31,698.90

    Choked flow through a hole

    Above about 0.9 bar gauge the air leaving a hole reaches the speed of sound and the mass flow depends only on the upstream pressure, temperature and hole area. A 3 mm hole at 7 bar loses about 0.4 m³/min (14 cfm) of free air through a sharp edge, and more if the edge is rounded. The compressor's specific power (kW per m³/min of free air delivered, from its data sheet or a CAGI sheet) converts the air to electrical power. Leaks lose air whenever the system is pressurised, including nights and weekends.

    Assumptions and limits

    • Ideal gas, isentropic choked flow; free air at 1.01325 bar and 20 °C.
    • Constant line pressure and compressor specific power.

    References

    • US Department of Energy and Compressed Air Challenge, Improving Compressed Air System Performance: A Sourcebook for Industry, 3rd ed., 2016.
    • White, F. M., Fluid Mechanics, 8th ed., McGraw-Hill, 2016 (compressible flow through a nozzle).

    Questions

    What do ten 3 mm leaks at 7 bar cost?
    With Cd = 0.61 they lose about 4.06 m³/min (144 cfm) of free air, which takes 26.4 kW of compressor power: 211,300 kWh or about 31,700 a year at 0.15 per kWh over 8,000 hours.
    How do I find the leaks?
    An ultrasonic detector finds leaks while the plant runs; a drop test (timing how fast pressure falls with production stopped) measures the total leak rate.

    Results depend on the figures and factors you enter and on the assumptions listed above. Use the factor set your reporting scheme requires. Read the disclaimer.