Gas Flow Through an Orifice Calculator (Choked and Subsonic)

When gas leaks or vents through a hole and the downstream pressure is low enough, the flow reaches the speed of sound in the hole and chokes. Beyond that point, lowering downstream pressure does not increase the flow. This calculator handles both choked and subsonic conditions.

Inputs

Advanced options (2)

Results

Mass flow rate
72.41
Flow condition
Choked (sonic at the orifice): flow does not increase as downstream pressure falls further
Critical pressure ratio
0.5283
Volume flow at 0 °C, 1.01325 bar (Nm³/h)
56.04
  • Ideal-gas, isentropic model. For relief valve sizing use API 520 methods; for real-gas effects at high pressure apply a compressibility factor.

RefENG-FLU-015
MethodIsentropic nozzle flow of an ideal gas with discharge coefficient
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Critical pressure ratior* = (2/(k+1))^(k/(k−1))r* = 0.5283; actual Pb/P0 = 0.1448
  2. Choked mass flowṁ = Cd·A·P0·√(k/(R·T0))·(2/(k+1))^((k+1)/(2(k−1)))ṁ = 0.02011 kg/s = 72.41 kg/h

Leak estimates

For air the critical pressure ratio is about 0.528, so any vessel above roughly 0.9 barg venting to atmosphere has choked flow. Choked flow is directly proportional to upstream absolute pressure, which makes leak-rate estimates for compressed air and gas systems straightforward.

Assumptions and limits

  • Ideal gas, isentropic expansion with a discharge coefficient.
  • Upstream velocity negligible (large vessel or pipe).

References

  • Shapiro, A. H., The Dynamics and Thermodynamics of Compressible Fluid Flow.
  • Perry's Chemical Engineers' Handbook, flow through orifices.

Questions

What is the critical pressure ratio for air?
About 0.528 for k = 1.4.
How much air leaks through a 1 mm hole at 7 bar gauge?
About 2.6 Nm³/h (0.9 g/s) with a discharge coefficient of 0.62. Running all year, that is over 22,000 Nm³ of compressed air from one small hole.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.