Why Darcy-Weisbach
Darcy-Weisbach is valid for any Newtonian fluid at any velocity, unlike Hazen-Williams, which only applies to water near room temperature. The Colebrook equation is solved by iteration here rather than approximated, so the friction factor matches the Moody chart.
Gases
For gases the result is accurate when the pressure drop is less than about 10% of the inlet pressure, because density is then roughly constant. For larger drops, split the line into sections or use a compressible-flow method.
Assumptions and limits
- Steady, fully developed flow in a full circular pipe.
- Constant density along the pipe.
- Roughness values for new pipe unless changed.
References
- Colebrook, C. F., Turbulent flow in pipes, J. Inst. Civil Eng., 1939.
- Crane Technical Paper 410, Flow of Fluids Through Valves, Fittings and Pipe.
- White, F. M., Fluid Mechanics.
Questions
- What velocity should I design for?
- Typical guides are 1 to 2.5 m/s for water distribution and pump discharge, 0.6 to 1.5 m/s for pump suction, and 15 to 30 m/s for low-pressure gases.
- Should I use inside or nominal diameter?
- Inside diameter. A 4-inch Schedule 40 steel pipe has an inside diameter of about 102.3 mm, not 100 mm.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.