Orifice Plate and Venturi Flow Calculator

Differential pressure meters such as orifice plates and venturis are the most common way to measure flow in process plants. This calculator converts between differential pressure and flow, and estimates the permanent pressure loss the meter causes.

Inputs

Results

Result
31.52 m³/h (138.8 US gpm)
Flow rate
31.52
Differential pressure
25
Diameter ratio, β = d/D
0.5
Approximate permanent pressure loss
18.27
  • Uses a constant Cd. ISO 5167 calculates Cd from β, Reynolds number and tapping type (Reader-Harris/Gallagher); use it for custody transfer or accurate metering.

RefENG-FLU-009
MethodQ = Cd·A₂·√(2ΔP/ρ) / √(1 − β⁴)
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Diameter ratio and velocity of approach factorβ = d/D; E = 1/√(1 − β⁴)β = 0.5, E = 1.033
  2. Flow equationQ = Cd·E·A₂·√(2ΔP/ρ)Q = 0.61 × 1.033 × 0.001963 × √(2 × 25,000 / 998.2) = 0.008755 m³/s

Orifice or venturi

An orifice plate is cheap and simple but loses most of its differential pressure permanently. A venturi recovers most of it, losing only about 10 to 15%, which saves pumping energy on large lines at higher purchase cost.

Assumptions and limits

  • Incompressible flow (liquids, or gases with small ΔP).
  • Constant discharge coefficient.

References

  • ISO 5167-1 to 5167-4, Measurement of fluid flow by pressure differential devices.
  • ASME MFC-3M.

Questions

Why does flow vary with the square root of ΔP?
Because ΔP is proportional to velocity squared. Doubling the flow needs four times the differential pressure, which limits a meter's useful range to about 3:1 or 4:1.
Can I use this for gases?
Only if the differential pressure is small compared with line pressure. Otherwise apply an expansibility factor as in ISO 5167.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.