NPSH Available Calculator

A pump cavitates when the pressure at its inlet falls close to the liquid's vapour pressure. NPSH available is the margin the suction system provides; it must exceed the NPSH the pump requires, read from its curve, by a safe amount.

Inputs

Advanced options (2)

Results

NPSH available
11.15
Margin over NPSHr
8.154
NPSHa / NPSHr
3.72
Vapour pressure used
7.382

    RefENG-FLU-007
    MethodNPSHa = (P_surface − P_vapour)/(ρg) + z_static − h_friction
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Vapour pressure and densityPv = 7.382 kPa, ρ = 992.2 kg/m³ at 40 °C
    2. Pressure head above vapour(Ps − Pv)/(ρg)(101.3 − 7.382) kPa / (992.2 × 9.80665) = 9.654 m
    3. NPSH availableNPSHa = pressure head + z − h_fNPSHa = 9.654 + 2 − 0.5 = 11.15 m

    Hot liquids

    Vapour pressure rises steeply with temperature. Water at 20 °C has a vapour pressure of about 2.3 kPa, but at 80 °C it is about 47 kPa, which removes nearly 5 m of NPSH. Hot water and boiler feed pumps usually need a flooded suction several metres high.

    Altitude

    Atmospheric pressure falls about 12 kPa per 1000 m of altitude. For an open tank, enter the local atmospheric pressure, not the sea-level value.

    Assumptions and limits

    • Water properties from the Buck vapour pressure and Tilton-Taylor density correlations unless overridden.
    • Velocity head at the surface negligible.

    References

    • ANSI/HI 9.6.1, Rotodynamic pumps: guideline for NPSH margin.
    • Buck, A. L., 1981/1996 vapour pressure equation.

    Questions

    How much NPSH margin do I need?
    The Hydraulic Institute recommends margin ratios from about 1.1 to 2.5 depending on the application. A common minimum is 1 m or 30% over NPSHr.
    Does suction pipe size matter?
    Yes. A smaller suction pipe raises friction loss and directly reduces NPSHa.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.