Typical design velocities
Water distribution and pump discharge lines usually run at 1 to 2.5 m/s (3 to 8 ft/s); pump suction lines lower, at 0.6 to 1.5 m/s, to protect NPSH. Saturated steam mains run at 25 to 40 m/s and compressed air at 6 to 10 m/s. Higher velocity means smaller, cheaper pipe but more pressure drop, noise and erosion.
Assumptions and limits
- Full pipe, uniform mean velocity.
References
- Continuity equation.
- CIBSE Guide C and ASHRAE Handbook, pipe sizing guidance.
Questions
- What pipe size for 50 m³/h of water?
- At 2 m/s, about 94 mm inside diameter, so a 4-inch (DN100) Schedule 40 pipe.
- Is velocity the only criterion?
- No. Check pressure drop per unit length too; long lines often need a bigger size than velocity alone suggests.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.