Pipe Velocity and Pipe Sizing Calculator

Pipe sizing usually starts from a sensible velocity. Enter the flow and a target velocity to get the inside diameter you need, or enter an existing pipe size to check the velocity it will run at.

Inputs

Results

Result
Inside diameter 94.03 mm (3.7 in)
Inside diameter
94.03
Velocity
2
Flow area
6,944
  • Choose the next standard pipe size with an inside diameter at least this large, then check pressure drop.

RefENG-FLU-005
MethodContinuity: Q = v·πD²/4
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Diameter from continuityD = √(4Q / (πv))D = √(4 × 0.01389 / (π × 2)) = 94.03 mm

Typical design velocities

Water distribution and pump discharge lines usually run at 1 to 2.5 m/s (3 to 8 ft/s); pump suction lines lower, at 0.6 to 1.5 m/s, to protect NPSH. Saturated steam mains run at 25 to 40 m/s and compressed air at 6 to 10 m/s. Higher velocity means smaller, cheaper pipe but more pressure drop, noise and erosion.

Assumptions and limits

  • Full pipe, uniform mean velocity.

References

  • Continuity equation.
  • CIBSE Guide C and ASHRAE Handbook, pipe sizing guidance.

Questions

What pipe size for 50 m³/h of water?
At 2 m/s, about 94 mm inside diameter, so a 4-inch (DN100) Schedule 40 pipe.
Is velocity the only criterion?
No. Check pressure drop per unit length too; long lines often need a bigger size than velocity alone suggests.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.