K method
Each fitting is given a loss coefficient K, the number of velocity heads it consumes. The total pressure drop is ΣK times the dynamic pressure ρv²/2. Add the result to the straight-pipe friction loss, or enter ΣK directly into the pipe pressure drop calculator.
Accuracy
Published K values vary by 30% or more between sources and fitting designs. The more refined 2-K and 3-K methods account for pipe size and Reynolds number; for critical systems use those or the manufacturer's flow data (Cv or Kv).
Assumptions and limits
- Turbulent flow.
- Fittings far enough apart not to interact.
References
- Crane Technical Paper 410.
- Hooper, W. B., The two-K method, Chem. Eng., 1981.
- White, F. M., Fluid Mechanics, minor losses.
Questions
- What is the K value of a 90° elbow?
- About 0.3 to 0.9 depending on radius and construction. Long-radius welded elbows are at the low end.
- How do I convert K to equivalent length?
- Equivalent length L = K × D / f, using the pipe friction factor f.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.