Darcy or Fanning
Two definitions are in use. The Darcy (Moody) factor, used in civil and mechanical engineering, is four times the Fanning factor used in many chemical engineering texts. Mixing them up gives a fourfold error in pressure drop.
Approximations
Swamee-Jain and Haaland are explicit formulas within about 1 to 2% of Colebrook over the normal turbulent range, which made them popular before iterative solutions were easy. With a computer there is no reason not to use Colebrook itself.
Assumptions and limits
- Fully developed flow in a circular pipe.
References
- Colebrook, C. F., 1939.
- Swamee, P. K. and Jain, A. K., J. Hydraulics Division ASCE, 1976.
- Haaland, S. E., J. Fluids Eng., 1983.
- Moody, L. F., Friction factors for pipe flow, 1944.
Questions
- What is the friction factor for smooth pipe at Re = 100,000?
- About 0.018 (Darcy).
- Does roughness matter in laminar flow?
- No. In laminar flow f = 64/Re for any pipe.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.