Weld Group Eccentric Load Calculator (Elastic Method)

When a bracket or plate is welded to a column face and loaded away from the weld, the welds must carry both a direct shear and a twisting moment. This calculator treats the weld as a line of unit width, finds its centroid and polar moment, adds the direct and torsional forces per unit length as vectors at every end and corner, and converts the largest into a required fillet weld size.

Inputs

Results

Fillet leg size required
7.179
Maximum force per unit length of weld
736.1
Throat thickness required
5.076
Utilisation of the leg size provided
89.7
%
Total weld length, L_w
400
Centroid distance from the left (vertical) line, x̄
25
Centroid height above the bottom, ȳ
100
Polar moment of the weld line, J_w
3,083
  • Elastic (vector) method treating the weld as a line, as in Blodgett. The instantaneous centre method and the directional strength increase for transverse welds give higher capacities. Check the base metal too.

RefENG-STR-028
MethodWeld as a line: f = √[(M·y/J_w)² + (P/L_w + M·x/J_w)²]; throat a = f/τ_allow; leg = a/0.707
UnitsSI
Date2026-11-24

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Weld treated as a line: length and centroidL_w = ΣL_i; x̄ = ΣL_ix_i/L_w; ȳ = ΣL_iy_i/L_wL_w = 400 mm; x̄ = 25 mm; ȳ = 100 mm
  2. Polar moment of the lineJ_w = Σ(L_i³/12 + L_i·r_i²)J_w = 3,083,333 mm³ (per unit throat)
  3. Force per unit length at the critical pointf_x = M·y/J_w; f_y = P/L_w + M·x/J_w; f = √(f_x² + f_y²)M = 15 kN·m; at (75, -100) mm: f_x = 486.5, f_y = 552.4, f = 736.1 N/mm
  4. Weld sizea = f/τ_allow; leg z = a/0.707a = 5.076 mm; z = 7.179 mm

Force per unit length at the weld ends and corners (from the centroid)

x (mm)y (mm)f (N/mm)f (kip/in)
-25-100490.92.803
-25100490.92.803
75-100736.14.203
75100736.14.203

Treating the weld as a line

Because a fillet weld is thin compared with its length, its section properties can be calculated per unit throat, as if the weld were a line. The direct load is shared uniformly along the total length, and the moment produces a force proportional to distance from the centroid, perpendicular to the radius. The point furthest from the centroid on the loaded side governs. Dividing the force per unit length by the allowable throat stress gives the throat, and dividing by 0.707 gives the leg of an equal-leg fillet.

Assumptions and limits

  • Rigid connected plate; fillet welds of equal size throughout the group.
  • Vertical load in the plane of the weld group; welds act in shear on the throat.
  • Elastic (vector) method; no strength increase for load direction.

References

  • Blodgett, O. W., Design of Welded Structures, James F. Lincoln Arc Welding Foundation, treating the weld as a line.
  • Salmon, C. G., Johnson, J. E. and Malhas, F. A., Steel Structures: Design and Behavior, eccentric welded connections.
  • AISC Steel Construction Manual, Part 8, eccentrically loaded weld groups.

Questions

What weld does the default C-shaped bracket need?
A C of two 100 mm flanges and a 200 mm web, with 75 kN acting 200 mm from the weld centroid, has a maximum force of 736 N/mm at the flange tips. At 145 MPa that needs a 5.1 mm throat or a 7.2 mm leg, so the 8 mm weld provided is used to 90 %.
What is J for an all-round box weld?
For a box b × d treated as a line, J_w = (b + d)³/6. A 100 × 200 mm box gives 4.5 × 10⁶ mm³.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.