Treating the weld as a line
Because a fillet weld is thin compared with its length, its section properties can be calculated per unit throat, as if the weld were a line. The direct load is shared uniformly along the total length, and the moment produces a force proportional to distance from the centroid, perpendicular to the radius. The point furthest from the centroid on the loaded side governs. Dividing the force per unit length by the allowable throat stress gives the throat, and dividing by 0.707 gives the leg of an equal-leg fillet.
Assumptions and limits
- Rigid connected plate; fillet welds of equal size throughout the group.
- Vertical load in the plane of the weld group; welds act in shear on the throat.
- Elastic (vector) method; no strength increase for load direction.
References
- Blodgett, O. W., Design of Welded Structures, James F. Lincoln Arc Welding Foundation, treating the weld as a line.
- Salmon, C. G., Johnson, J. E. and Malhas, F. A., Steel Structures: Design and Behavior, eccentric welded connections.
- AISC Steel Construction Manual, Part 8, eccentrically loaded weld groups.
Questions
- What weld does the default C-shaped bracket need?
- A C of two 100 mm flanges and a 200 mm web, with 75 kN acting 200 mm from the weld centroid, has a maximum force of 736 N/mm at the flange tips. At 145 MPa that needs a 5.1 mm throat or a 7.2 mm leg, so the 8 mm weld provided is used to 90 %.
- What is J for an all-round box weld?
- For a box b × d treated as a line, J_w = (b + d)³/6. A 100 × 200 mm box gives 4.5 × 10⁶ mm³.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.