Fillet Weld Strength Calculator

Fillet welds carry load through shear on their throat, the smallest section across the weld. This calculator gives the allowable load for a set of fillet welds and the leg size needed for a given load, using the throat method from structural welding codes.

Inputs

Results

Allowable load on the welds
184
Utilisation
81.5
%
Leg size required for the load
4.89
Throat thickness
4.243
Throat shear stress under the load
117.9
  • Simplified method ignoring load direction (transverse welds are stronger). Check base metal shear and the minimum and maximum fillet sizes in your code.

RefENG-WLD-004
MethodThroat a = 0.707z; capacity = τ_allow·a·L; τ_allow = 0.30·F_EXX (AWS D1.1 allowable stress)
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Throata = 0.707za = 4.243 mm
  2. Allowable shearτ = k·F_EXXτ = 144.6 MPa
  3. CapacityP = τ·a·L·nP = 144.6 × 4.243 × 150 × 2 = 184 kN

Rule of thumb

With E70 electrodes and the AWS allowable of 0.30 F_EXX, each millimetre of fillet leg carries about 102 N per millimetre of weld length (about 0.93 kip per inch per sixteenth of an inch of leg in US practice).

Assumptions and limits

  • Equal-leg fillet welds; load shared equally.
  • Throat shear governs; directional strength increase not used.

References

  • AWS D1.1, Structural welding code: steel, Table 2.3.
  • AISC 360, section J2.4.
  • EN 1993-1-8, Eurocode 3: design of joints, 4.5.3.

Questions

What load can two 6 mm × 150 mm fillet welds carry?
About 184 kN allowable with E70 electrodes (145 MPa on the throat).
What size fillet do I need for 150 kN?
About 4.9 mm leg for two 150 mm welds, so a 5 mm fillet, subject to the minimum size for the plate thickness.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.