Rule of thumb
With E70 electrodes and the AWS allowable of 0.30 F_EXX, each millimetre of fillet leg carries about 102 N per millimetre of weld length (about 0.93 kip per inch per sixteenth of an inch of leg in US practice).
Assumptions and limits
- Equal-leg fillet welds; load shared equally.
- Throat shear governs; directional strength increase not used.
References
- AWS D1.1, Structural welding code: steel, Table 2.3.
- AISC 360, section J2.4.
- EN 1993-1-8, Eurocode 3: design of joints, 4.5.3.
Questions
- What load can two 6 mm × 150 mm fillet welds carry?
- About 184 kN allowable with E70 electrodes (145 MPa on the throat).
- What size fillet do I need for 150 kN?
- About 4.9 mm leg for two 150 mm welds, so a 5 mm fillet, subject to the minimum size for the plate thickness.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.