Sheet Metal Bend Allowance and Flat Length Calculator

When sheet metal bends, the outside stretches and the inside compresses, so the flat blank is shorter than the sum of the outside dimensions. This calculator uses the K-factor method to give the bend allowance, bend deduction and the flat length for a single bend.

Inputs

Results

Flat blank length
76.52
Bend allowance
4.524
Bend deduction
3.476
Outside setback
4

    RefENG-WLD-006
    MethodBA = (π/180)·A·(R + K·T); OSSB = tan(A/2)·(R + T); BD = 2·OSSB − BA
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Bend allowanceBA = (π/180)·A·(R + K·T)BA = 4.524 mm
    2. Outside setbackOSSB = tan(A/2)·(R + T)OSSB = 4 mm
    3. Bend deduction and flat lengthBD = 2·OSSB − BA; flat = L₁ + L₂ − BDBD = 3.476 mm; flat = 76.52 mm

    Calibrate the K-factor

    K depends on material, tooling and bending method. Bend a test piece, measure it, and back-calculate K for your press brake; then use that value for production. For several bends, subtract one bend deduction per bend from the sum of the outside flange lengths.

    Assumptions and limits

    • Constant thickness; flange lengths measured to the outside mould line (intersection of outside surfaces).

    References

    • Machinery's Handbook, sheet metal bending.
    • SolidWorks and Inventor sheet metal K-factor tables.

    Questions

    What is the flat length of a 50 × 30 mm bracket in 2 mm sheet?
    About 76.5 mm with a 2 mm inside radius and K = 0.44: the bend deduction is about 3.5 mm.
    What is the K-factor?
    The position of the neutral axis as a fraction of thickness from the inside surface: 0.5 would be the middle; real bends are usually 0.3 to 0.45.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.