Welding Heat Input Calculator (Arc Energy)

Heat input controls the cooling rate of a weld and so its hardness, toughness and distortion. Welding procedure specifications limit it. This calculator gives arc energy and heat input from the welding parameters, in both the European (with process efficiency) and ASME forms.

Inputs

Results

Heat input (EN 1011-1)
0.8294
Arc energy (ISO/TR 18491, ASME without efficiency)
1.037
ASME Section IX heat input (J/in)
26,335

    RefENG-WLD-001
    MethodArc energy E = V·I·60/(1000·S) kJ/mm (S in mm/min); heat input Q = k·E
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Arc energyE = V·I/(1000·S) with S in mm/sE = 24 × 180 / (1000 × 4.167) = 1.037 kJ/mm
    2. Heat inputQ = k·EQ = 0.8 × 1.037 = 0.8294 kJ/mm
    3. ASME QW-409.126,335 J/in

    Arc energy or heat input?

    EN ISO 15614-1 and ISO/TR 18491 now record arc energy, without the efficiency factor; heat input with k is still used for cooling time and preheat calculations in EN 1011-2. ASME Section IX QW-409.1 uses arc energy in J/in. For waveform-controlled power sources, use instantaneous energy or power from the machine display instead of V × I.

    Assumptions and limits

    • Average voltage and current measured at the arc; steady travel speed.

    References

    • EN 1011-1, Welding: recommendations for welding of metallic materials, general guidance for arc welding.
    • ASME Boiler and Pressure Vessel Code Section IX, QW-409.1.
    • ISO/TR 18491, measurement of energy for waveform-controlled arc welding.

    Questions

    What is the heat input for 24 V, 180 A at 250 mm/min?
    Arc energy 1.04 kJ/mm; with k = 0.8 for MAG the heat input is 0.83 kJ/mm (26.3 kJ/in arc energy).
    Why does heat input matter?
    Low heat input cools the weld fast and can make the heat-affected zone hard and crack-sensitive; high heat input lowers toughness and increases distortion.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.