Weld Cooling Time t8/5 Calculator (EN 1011-2)

The time a steel weld takes to cool from 800 to 500 °C, t8/5, largely decides the hardness and toughness of the heat-affected zone. This calculator uses the EN 1011-2 equations to estimate it from heat input, preheat, plate thickness and joint type, and tells you whether heat flow is two- or three-dimensional.

Inputs

Results

Cooling time t8/5
6.643
Heat flow
Three-dimensional (thick plate): use t3
Transition thickness
15.66
t8/5 for two-dimensional flow
4.072
t8/5 for three-dimensional flow
6.643

    RefENG-WLD-002
    MethodEN 1011-2 Annex D: 3D t = (6700 − 5T₀)·Q·[1/(500 − T₀) − 1/(800 − T₀)]·F₃; 2D t = (4300 − 4.3T₀)·10⁵·(Q²/d²)·[1/(500 − T₀)² − 1/(800 − T₀)²]·F₂
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Transition thicknessd_t = √[(4300 − 4.3T₀)·10⁵·Q·a₂ / ((6700 − 5T₀)·a₃)]d_t = 15.66 mm
    2. Three-dimensionalt3 = 6.643 s (F₃ = 1)
    3. Two-dimensionalt2 = 4.072 s (F₂ = 1)

    Using the result

    Short cooling times (below about 5 s) risk hard, crack-prone martensite in higher carbon equivalent steels; long times (above about 20 to 30 s) can reduce toughness in fine-grained and thermomechanical steels. Steel makers often give an acceptable t8/5 window.

    Assumptions and limits

    • Equations of EN 1011-2 Annex D for non-alloy and low-alloy ferritic steels.
    • Heat input already includes the process efficiency factor.

    References

    • EN 1011-2, Welding: recommendations for welding of metallic materials, arc welding of ferritic steels, Annex D.
    • SEW 088, Weldable fine-grained structural steels.

    Questions

    What is t8/5 for 1 kJ/mm on 20 mm plate with 100 °C preheat?
    About 6.6 s for bead-on-plate. The plate is thicker than the 15.7 mm transition thickness, so three-dimensional heat flow applies.
    How does preheat change t8/5?
    Preheat slows cooling. Raising it from 20 to 150 °C lengthens t8/5 by about 50 % in thick plate and nearly doubles it in thin plate at the same heat input.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.