Using the result
Short cooling times (below about 5 s) risk hard, crack-prone martensite in higher carbon equivalent steels; long times (above about 20 to 30 s) can reduce toughness in fine-grained and thermomechanical steels. Steel makers often give an acceptable t8/5 window.
Assumptions and limits
- Equations of EN 1011-2 Annex D for non-alloy and low-alloy ferritic steels.
- Heat input already includes the process efficiency factor.
References
- EN 1011-2, Welding: recommendations for welding of metallic materials, arc welding of ferritic steels, Annex D.
- SEW 088, Weldable fine-grained structural steels.
Questions
- What is t8/5 for 1 kJ/mm on 20 mm plate with 100 °C preheat?
- About 6.6 s for bead-on-plate. The plate is thicker than the 15.7 mm transition thickness, so three-dimensional heat flow applies.
- How does preheat change t8/5?
- Preheat slows cooling. Raising it from 20 to 150 °C lengthens t8/5 by about 50 % in thick plate and nearly doubles it in thin plate at the same heat input.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.