Column Buckling Calculator (Euler and Johnson)

Long, slender columns fail by buckling sideways at loads well below the crushing strength of the material. This calculator finds the critical load using Euler's formula for slender members and the Johnson parabola for stockier ones where yielding and buckling interact.

Inputs

Results

Critical buckling load
607.5
Allowable load (critical ÷ FS)
363.8
Slenderness ratio, KL/r
77.46
Transition slenderness, C_c
125.7
Critical stress
202.5
Governing formula
Johnson (inelastic buckling)

    RefENG-STR-003
    MethodEuler σ = π²E/(KL/r)²; Johnson σ = F_y[1 − F_y(KL/r)²/(4π²E)] below C_c = √(2π²E/F_y)
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Radius of gyration and slendernessr = √(I/A); λ = KL/rr = 38.73 mm; λ = 77.46
    2. Transition slendernessC_c = √(2π²E/F_y)C_c = 125.7
    3. Critical stressσ = F_y[1 − F_y·λ²/(4π²E)]σ = 202.5 MPa; P_cr = 607.5 kN

    Design codes

    Steel design codes such as AISC 360 and Eurocode 3 use column curves that also allow for initial crookedness and residual stresses, giving lower capacities than this idealised result. Use this calculator for machine members, struts and early sizing, and the code for structural design.

    Assumptions and limits

    • Straight, prismatic, centrally loaded column.
    • Buckling about the axis with the least second moment of area.

    References

    • Timoshenko, S. P. and Gere, J. M., Theory of Elastic Stability.
    • AISC 360, Commentary Table C-A-7.1, effective length factors.

    Questions

    What is the Euler buckling load formula?
    P = π²EI/(KL)². It applies when the slenderness ratio is above about 126 for mild steel (C_c at 250 MPa yield).
    What load can the default 3 m pinned column carry?
    Slenderness is about 77, so the Johnson formula applies: about 607 kN critical, or 364 kN with a factor of safety of 1.67.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.