Three cases
When e = M/P is within N/6 the whole plate stays in contact and the pressure is trapezoidal. Beyond N/6 the plate tends to lift at the heel. If the anchors are ignored, the pressure becomes triangular over a length 3(N/2 − e), which needs the resultant inside the plate. With anchors, the classic elastic method treats the bolts as springs: strain compatibility of the rigid plate rotating about the end of the bearing zone gives a cubic equation for the bearing length Y, after which equilibrium gives the bolt tension and the peak pressure.
Assumptions and limits
- Rigid plate; linear (triangular) bearing pressure; concrete carries no tension.
- Anchor bolts behave elastically with modular ratio n = E_s/E_c and are not pretensioned.
- Moment about one axis only; axial load is compressive.
References
- Blodgett, O. W., Design of Welded Structures, James F. Lincoln Arc Welding Foundation, column bases with moment.
- Salmon, C. G., Johnson, J. E. and Malhas, F. A., Steel Structures: Design and Behavior, column base plates with moment.
Questions
- What does the default base plate give?
- A 400 × 300 mm plate with 300 kN and 50 kN·m has e = 167 mm, beyond N/6. With two M24 anchors 150 mm from the centre and n = 8, the bearing length is 211 mm, the anchors carry 39.8 kN in total (19.9 kN each) and the peak bearing pressure is 10.7 MPa.
- What if the moment is only 10 kN·m?
- Then e = 33 mm is inside N/6, the plate stays in full contact and the pressure varies from 3.75 MPa to 1.25 MPa with no anchor tension.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.