Footing Soil Pressure Calculator (Eccentric and Biaxial Loads)

A footing that carries a moment as well as a vertical load presses harder on one side than the other. This calculator gives the soil pressure under a rigid rectangular footing for moments about one or both axes. Inside the kern the familiar P/A ± M/Z formula applies; outside it, part of the footing lifts off, and the calculator solves for the contact zone and peak pressure.

Inputs

Results

Maximum soil pressure, q_max
352.8
Minimum soil pressure
0
Average pressure, P/(B·L)
160
Contact
Partial contact (outside the kern)
Footing area in contact with the soil
98.4
%
Eccentricity along B, e_B = M_B/P
0.3125
Eccentricity along L, e_L = M_L/P
0.15
Utilisation of the allowable bearing pressure
88.2
%
  • The load is outside the kern, so part of the footing lifts off. Many designers keep the resultant within the kern under permanent loads, and limit the uplift area under transient loads.
  • Rigid footing with a linear pressure distribution. Check bearing capacity, settlement and sliding, and design the footing itself to your code.

RefENG-STR-035
MethodInside the kern: q = P/A(1 ± 6e_B/B ± 6e_L/L); outside: rigid footing on no-tension soil, contact zone found by iteration
UnitsSI
Date2026-11-24

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Eccentricitiese_B = M_B/P; e_L = M_L/Pe_B = 0.3125 m; e_L = 0.15 m
  2. Kern check6|e_B|/B + 6|e_L|/L ≤ 1 for full contact0.75 + 0.45 = 1.2
  3. No-tension solutionFind q = q₀ + a·x + b·y ≥ 0 such that ∫q dA = P, ∫x·q dA = P·e_B, ∫y·q dA = P·e_L over the contact areaContact area 98.4 % of the footing; q_max = 352.8 kPa at the most loaded corner

Pressure at the corners (x along B, y along L, from the centre)

x (m)y (m)q (kPa)q (psf)
-1.25-100
1.25-1207.94,341
1.251352.87,368
-1.251111.82,335

Inside and outside the kern

For a rectangle, the load stays in full contact if 6e_B/B + 6e_L/L ≤ 1, a diamond-shaped zone around the centre. Under one-way eccentricity beyond B/6, the pressure becomes triangular with a peak of 2P/(3L(B/2 − e)). With moments about both axes the contact zone is a polygon whose edge is the line of zero pressure. The calculator finds the plane of pressure that has zero value along that line and balances the load and both moments, by repeated exact integration over the clipped polygon. Published design charts for biaxially loaded footings solve the same problem; this gives the value directly.

Assumptions and limits

  • Rigid footing; soil acts as a bed of independent springs (linear pressure); no tension between footing and soil.
  • Vertical load and moments applied at the centre of the footing base; P includes the footing and backfill weight.

References

  • Bowles, J. E., Foundation Analysis and Design, footings with eccentric and biaxial loads.
  • Highter, W. H. and Anders, J. C., 1985, Dimensioning footings subjected to eccentric loads, Journal of Geotechnical Engineering, ASCE 111(5).
  • Das, B. M., Principles of Foundation Engineering, eccentrically loaded foundations.

Questions

What is the peak pressure for the default footing?
A 2.5 × 2 m footing with 800 kN and moments of 250 and 120 kN·m has e_B = 0.3125 m and e_L = 0.15 m, outside the kern (1.2 > 1). One corner lifts off, 98.4 % of the base stays in contact, and the most loaded corner reaches 352.8 kPa against an average of 160 kPa.
What if there is only the 250 kN·m moment?
Then e_B = 0.3125 m is inside B/6 = 0.417 m, and the pressure varies linearly from 280 kPa to 40 kPa across the footing.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.