Inside and outside the kern
For a rectangle, the load stays in full contact if 6e_B/B + 6e_L/L ≤ 1, a diamond-shaped zone around the centre. Under one-way eccentricity beyond B/6, the pressure becomes triangular with a peak of 2P/(3L(B/2 − e)). With moments about both axes the contact zone is a polygon whose edge is the line of zero pressure. The calculator finds the plane of pressure that has zero value along that line and balances the load and both moments, by repeated exact integration over the clipped polygon. Published design charts for biaxially loaded footings solve the same problem; this gives the value directly.
Assumptions and limits
- Rigid footing; soil acts as a bed of independent springs (linear pressure); no tension between footing and soil.
- Vertical load and moments applied at the centre of the footing base; P includes the footing and backfill weight.
References
- Bowles, J. E., Foundation Analysis and Design, footings with eccentric and biaxial loads.
- Highter, W. H. and Anders, J. C., 1985, Dimensioning footings subjected to eccentric loads, Journal of Geotechnical Engineering, ASCE 111(5).
- Das, B. M., Principles of Foundation Engineering, eccentrically loaded foundations.
Questions
- What is the peak pressure for the default footing?
- A 2.5 × 2 m footing with 800 kN and moments of 250 and 120 kN·m has e_B = 0.3125 m and e_L = 0.15 m, outside the kern (1.2 > 1). One corner lifts off, 98.4 % of the base stays in contact, and the most loaded corner reaches 352.8 kPa against an average of 160 kPa.
- What if there is only the 250 kN·m moment?
- Then e_B = 0.3125 m is inside B/6 = 0.417 m, and the pressure varies linearly from 280 kPa to 40 kPa across the footing.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.