How the checks work
Soil behind the wall pushes on a vertical plane rising from the back of the heel, so the soil standing on the heel counts as part of the wall. The thrust from soil (triangular) and surcharge (rectangular) is resisted by the weight of the concrete and the soil over the heel. Overturning compares moments about the toe. Sliding compares the friction under the base, plus passive resistance in front if the soil there is permanent, with the horizontal thrust. The resultant of all forces gives the bearing pressure: trapezoidal if it stays in the middle third of the base, triangular if not.
Factors of safety of about 2 for overturning and 1.5 for sliding are traditional in allowable stress practice; limit state codes use partial factors instead.
Assumptions and limits
- Level, drained, cohesionless backfill; Rankine active pressure on a vertical virtual back; no wall friction.
- Stem back face vertical, front face battered; per metre length of wall.
- Base friction from δ; passive resistance only if selected; no water pressure or seismic load.
References
- Das, B. M., Principles of Foundation Engineering, retaining walls: stability checks.
- Bowles, J. E., Foundation Analysis and Design, cantilever retaining walls.
- Craig, R. F., Craig's Soil Mechanics, lateral earth pressure and retaining structures.
Questions
- Does the default wall pass?
- Yes. A 4 m stem on a 3.8 m base (1 m toe, 2.4 m heel, 0.5 m thick) with γ = 18 kN/m³, φ = 30° and 10 kPa surcharge has a factor of safety of 4.62 against overturning and 1.55 against sliding with δ = 25°. The resultant is 0.11 m off centre, inside the middle third, giving 77 kPa at the toe and 55 kPa at the heel.
- What thrust does the backfill exert?
- Over the 4.5 m height to the underside of the base, K_a = 1/3 gives 60.75 kN/m from the soil and 15 kN/m from the surcharge, 75.75 kN/m in total, with an overturning moment of 124.9 kN·m per metre.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.