Lateral Earth Pressure Calculator (Rankine, Retaining Walls)

A retaining wall must resist the sideways push of the soil behind it. This calculator uses Rankine theory to give the earth pressure coefficients, the total thrust per metre of wall including surcharge, where it acts, and the overturning moment for stability and stem design.

Inputs

Results

Total thrust per metre of wall
37
Active coefficient, K_a
0.3333
At-rest coefficient, K₀
0.5
Passive coefficient, K_p
3
Pressure at the base
21.33
Height of resultant above the base
1.135
Overturning moment per metre about the base
42
  • No water pressure is included: drain the backfill or add hydrostatic pressure, which can double the load. Sloping backfill, wall friction and seismic loads need Coulomb or code methods.

RefENG-STR-010
MethodRankine: K_a = (1 − sinφ)/(1 + sinφ); P_a = ½K_aγH² + K_a·q·H; K₀ = 1 − sinφ
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. CoefficientsK_a = (1 − sinφ)/(1 + sinφ); K₀ = 1 − sinφ; K_p = 1/K_aK_a = 0.3333, K₀ = 0.5, K_p = 3
  2. Soil thrust (triangle)P₁ = ½Kγ H²27 kN/m at H/3
  3. Surcharge thrust (rectangle)P₂ = K·q·H10 kN/m at H/2
  4. ResultantP = 37 kN/m at 1.135 m; M = 42 kN·m/m

Active or at rest?

Cantilever walls that can rotate slightly mobilise active pressure, the lowest value. Basement walls and propped walls cannot move and see at-rest pressure, about 50 % higher for typical sands. Passive pressure in front of the toe resists sliding but needs significant movement to develop.

Assumptions and limits

  • Cohesionless, dry, level backfill; vertical smooth wall back.
  • Uniform surcharge over the full backfill.

References

  • Rankine, W. J. M., 1857.
  • Das, B. M., Principles of Geotechnical Engineering, chapter on lateral earth pressure.
  • EN 1997-1, Eurocode 7.

Questions

What is the active thrust on a 3 m wall in sand?
With γ = 18 kN/m³, φ = 30° and 10 kPa surcharge, about 37 kN per metre of wall (27 kN from soil, 10 kN from surcharge).
What is K_a for φ = 30°?
One third. K₀ is 0.5 and K_p is 3.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.