Remaining Life from Thickness Readings

Thickness readings taken over time show how fast a pipe or vessel wall is thinning. This calculator turns them into long-term and short-term corrosion rates, the remaining life before the wall reaches its minimum required thickness, and a next inspection date.

Inputs

Advanced options (1)

Results

Remaining life
10
Long-term corrosion rate
0.2
Short-term corrosion rate
0.15
Next inspection within
5

    RefENG-MAT-021
    MethodRate = Δthickness / Δtime; RL = (t_actual − t_required) / rate
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Long-term rateLT = (t_initial − t_actual) / yearsLT = (12 − 10) / 10 = 0.2 mm/y
    2. Short-term rateST = (t_previous − t_actual) / yearsST = (10.6 − 10) / 4 = 0.15 mm/y
    3. Remaining life using the higher rateRL = (t_actual − t_required) / rateRL = (10 − 8) / 0.2 = 10 years
    4. Next inspectionLesser of RL/2 and the maximum intervalmin(5, 10) = 5 years

    Which rate to use

    The long-term rate averages corrosion since the component was new; the short-term rate reflects recent conditions. Inspection codes generally use the higher of the two, so a recent increase in corrosion shortens the predicted life. A large difference between them is worth investigating.

    Inspection interval

    Common practice in pressure vessel and piping inspection codes is to inspect again within half the remaining life, subject to a maximum interval. Check the exact rule in the code that governs your equipment.

    Assumptions and limits

    • Readings taken at the same location (thickness monitoring location).
    • Corrosion continues at the governing rate.
    • Minimum required thickness already calculated for the design conditions.

    References

    • API 510, Pressure Vessel Inspection Code.
    • API 570, Piping Inspection Code.

    Questions

    What if the current reading is thicker than the previous one?
    That usually means measurement scatter or a different location. The calculator then shows a zero or negative short-term rate and uses the long-term rate.
    Where does minimum required thickness come from?
    From a pressure design calculation for the shell, head or pipe, plus any structural minimum. See the shell and pipe wall thickness calculators.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.