MAWP Calculator

MAWP is the highest pressure a vessel can safely run at, set by its weakest pressure part. This calculator works back from actual or measured thickness to the allowable pressure of the shell and the heads in the corroded condition, and shows which one limits the vessel.

Inputs

Results

MAWP (governing)
1.525
Shell allowable pressure
1.525
Head allowable pressure
1.794
Governing component
Shell
  • Corroded condition, first-principles basis. Code MAWP (ASME VIII, EN 13445) uses code formulas and may also be limited by nozzles, flanges and static head.

RefENG-PVH-008
MethodShell P = S·E·t/R; heads by inverse membrane and plate formulas
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Corroded thicknessesshell 6.5 mm, head 6.5 mm
  2. ShellP = S·E·t / RP = 138 × 0.85 × 6.5 / 500 = 1.525 MPa
  3. Head (inverse of head thickness formula)P = 1.794 MPa
  4. Governing MAWPlower of shell and head1.525 MPa

Using inspection thickness

After an in-service inspection, enter the lowest measured thicknesses with the remaining corrosion allowance to see whether the vessel can still operate at its design pressure, or whether it needs rerating.

Other limits

In a real vessel MAWP may be set by a flange rating, nozzle reinforcement, liquid static head or external loads rather than by the shell or head. Treat this result as the pressure-part limit only.

Assumptions and limits

  • Internal pressure only.
  • Thicknesses reduced by the full corrosion allowance.
  • Same allowable stress for shell and heads.

References

  • ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, UG-27, UG-32, UG-98.
  • API 510, Pressure Vessel Inspection Code (rerating).

Questions

Is MAWP the same as design pressure?
Not always. Design pressure is what the vessel was designed for; MAWP is what its actual thicknesses can carry and is often a little higher.
Should I include corrosion allowance?
MAWP is normally stated in the corroded condition, so the allowance is subtracted. Enter zero to see the new, uncorroded value.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.