Using inspection thickness
After an in-service inspection, enter the lowest measured thicknesses with the remaining corrosion allowance to see whether the vessel can still operate at its design pressure, or whether it needs rerating.
Other limits
In a real vessel MAWP may be set by a flange rating, nozzle reinforcement, liquid static head or external loads rather than by the shell or head. Treat this result as the pressure-part limit only.
Assumptions and limits
- Internal pressure only.
- Thicknesses reduced by the full corrosion allowance.
- Same allowable stress for shell and heads.
References
- ASME Boiler and Pressure Vessel Code, Section VIII, Division 1, UG-27, UG-32, UG-98.
- API 510, Pressure Vessel Inspection Code (rerating).
Questions
- Is MAWP the same as design pressure?
- Not always. Design pressure is what the vessel was designed for; MAWP is what its actual thicknesses can carry and is often a little higher.
- Should I include corrosion allowance?
- MAWP is normally stated in the corroded condition, so the allowance is subtracted. Enter zero to see the new, uncorroded value.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.