Pipe Support Span Calculator

Pipes sag and bend between supports under their own weight and contents. This calculator finds the largest spacing that keeps bending stress and sag within limits. The sag limit usually governs small pipes and the stress limit large ones.

Inputs

Advanced options (2)

Results

Maximum support span
4.479
Span limited by stress
7.661
Span limited by sag
4.479
Total weight per length
29.29
  • Straight horizontal pipe only. Reduce spans at valves, flanges, bends and concentrated loads, and check standard span tables (MSS SP-58) for your service.

RefENG-PVH-004
MethodBeam theory: stress span L = √(k_m·Z·S / w); deflection span L = (k_d·E·I·δ / w)^¼
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Section propertiesI = π(OD⁴ − ID⁴)/64; Z = 2I/ODI = 3,010,519 mm⁴; Z = 52,678 mm³
  2. Weight per metrew = pipe + contents + insulationw = 29.29 kg/m = 287.2 N/m
  3. Stress-limited spanM = wL²/8 → L = √(8ZS/w)L = 7.661 m
  4. Sag-limited spanδ = 5wL⁴/(384EI)L = 4.479 m

Which span condition

A single span between two supports is simply supported, the conservative case. A long straight run over many supports behaves closer to a continuous beam, which allows a longer span. Real practice uses the simply supported value or a factor between the two.

Sag and drainage

A sag limit of about 2.5 mm (0.1 in) is common to avoid pockets that hold liquid in gas lines or condensate in steam lines.

Assumptions and limits

  • Uniformly distributed load.
  • No concentrated loads, wind or seismic.
  • Linear elastic beam behaviour.

References

  • MSS SP-58, Pipe hangers and supports.
  • ASME B31.1 Table 121.5 suggested support spacing.
  • Roark's Formulas for Stress and Strain, beams.

Questions

Why is the hydrotest case important?
Gas lines are tested with water, so supports must carry the water-filled weight during testing even if the line normally carries gas.
What allowable stress should I use?
Many designers limit weight stress to around 30 to 40 MPa for carbon steel so that pressure and thermal stresses still fit within code limits.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.