Guided cantilever method
The perpendicular leg is treated as a beam fixed at one end and guided at the other, deflected by the expansion. Setting the bending stress equal to the allowable displacement stress gives the minimum leg length. The method is conservative for most layouts and is a standard hand check before detailed stress analysis.
Allowable stress range
Piping codes define an allowable displacement stress range from the cold and hot allowable stresses and the number of thermal cycles. For carbon steel below creep temperatures, values around 150 to 200 MPa are typical.
Assumptions and limits
- Anchors are rigid; guides allow axial movement only.
- Expansion from installation to operating temperature.
- No friction or support loads included.
References
- ASME B31.3, Process Piping, para. 302.3.5 (displacement stress range).
- Kellogg, M. W., Design of Piping Systems.
Questions
- How much does steel pipe expand?
- About 1.2 mm per metre per 100 °C for carbon steel, and about 1.7 mm for stainless steel.
- Where should the loop go?
- Midway between anchors is usual, with guides on each side to keep movement axial.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.