Barlow formula
Barlow uses the outside diameter and assumes uniform hoop stress through the wall. Using the outside diameter makes it slightly conservative compared with the mean-diameter form, and it is the basis of the pressure design formulas in most piping codes.
Mill tolerance
Seamless and welded pipe is usually allowed to be up to 12.5% thinner than nominal. Dividing by (1 − 0.125) makes sure the thinnest permitted pipe still has the required wall.
Assumptions and limits
- Internal pressure only; no external loads, bending or thermal stress.
- Straight pipe; bends and branches need extra checks.
References
- ASME B31.3, Process Piping, para. 304.1.
- ASME B31.1, Power Piping.
- Barlow, P., hoop stress formula.
Questions
- Which schedule should I choose?
- Pick the lightest standard schedule whose nominal wall is at least the minimum nominal wall shown here, for example from ASME B36.10M tables.
- Why does the code formula give a slightly different result?
- ASME B31.3 uses t = PD/(2(SEW + PY)), where Y depends on temperature and material. At moderate pressures the difference is small.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.