Weight-loss coupons are the simplest way to measure corrosion in a process stream, cooling water system or lab test. Weigh the coupon before exposure and again after cleaning off the corrosion products, then enter the mass loss with the coupon area and exposure time.

Inputs

Results

Corrosion rate
0.08292
Corrosion rate
3.265
Typical rating for steel
Excellent (1 to 5 mpy)

    RefENG-MAT-020
    MethodCR = K·W / (A·T·ρ), ASTM G1 / G31 form
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Corrosion rate in mm/y (W in g, A in cm², T in h, ρ in g/cm³)CR = 8.76×10⁴ × W / (A × T × ρ)CR = 87600 × 0.025 / (20 × 168 × 7.86) = 0.08292 mm/y
    2. Convert to mils per yearmpy = mm/y ÷ 0.02540.08292 ÷ 0.0254 = 3.265 mpy

    Good coupon practice

    Clean coupons to the procedure in ASTM G1 so that only metal lost to corrosion is counted, and correct for any metal removed by the cleaning itself using a blank coupon. Inspect for pitting too: a weight-loss rate assumes uniform attack and can badly understate localised corrosion.

    Units

    Rates are given in millimetres per year and mils per year (thousandths of an inch per year). One mm/y equals about 39.4 mpy. The rating bands shown are a common guide for carbon steel equipment.

    Assumptions and limits

    • Uniform corrosion over the whole exposed area.
    • A year of 8760 hours, as in ASTM G1.

    References

    • ASTM G1, Preparing, cleaning and evaluating corrosion test specimens.
    • ASTM G31, Laboratory immersion corrosion testing of metals.
    • NACE SP0775, Preparation and use of corrosion coupons in oilfield operations.

    Questions

    What is an acceptable corrosion rate for carbon steel?
    Many cooling water and oilfield programmes target below about 2 to 5 mpy (0.05 to 0.13 mm/y) for carbon steel.
    How do I measure the area?
    Include all faces and edges of the coupon, minus any area masked by the holder.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.