In US units
In inches per hour the same formula is often written PR = 96.3 × gpm ÷ (S × L) with spacings in feet; 96.3 converts gallons per minute over square feet to inches per hour. A triangular layout covers each sprinkler's share with 0.866·S² instead of S², giving better overlap. Application rates above the soil intake rate cause ponding; on slopes and on crusting soils the safe rate is lower still.
Assumptions and limits
- All sprinklers run at the same flow; full-circle sprinklers with even overlap.
- Gross depth already allows for application efficiency.
References
- Keller, J. and Bliesner, R. D., Sprinkle and Trickle Irrigation, Van Nostrand Reinhold, 1990.
- USDA Natural Resources Conservation Service, National Engineering Handbook, Part 623, Chapter 11: Sprinkle Irrigation.
Questions
- What is the application rate of 1.2 m³/h sprinklers at 12 m × 18 m?
- 5.56 mm/h, so applying 40 mm takes 7.2 hours; a hectare needs 47 sprinklers drawing 56.4 m³/h.
- What happens if the rate is higher than the infiltration rate?
- Water ponds and runs off, so less reaches the roots and the field is unevenly watered. Choose a lower rate or apply in shorter cycles.
Results depend on the figures you enter and on the assumptions listed above; field, animal and product conditions vary. Read the disclaimer.