Drip Irrigation Calculator (Flow, Application Rate and Run Time)

Drip irrigation applies water slowly through emitters, so run times are measured in hours rather than minutes. This calculator works out the average application rate over the field from emitter flow and spacing, how long to run for a given depth, how many emitters you need and how many zones your pump can supply at once.

Results are estimates. Follow local agronomy advice and product labels.

Inputs

%

Results

Run time per zone
1.667
Application rate
3.333
Gross depth
5.556
Emitters
20,833.3
System flow if run as one zone
33.33
Zones needed for the pump
2
Time to irrigate every zone
3.333

    RefAGR-IRR-004
    MethodRate = q ÷ (emitter spacing × lateral spacing); run time = gross depth ÷ rate; zones = system flow ÷ pump capacity
    UnitsSI
    Date2026-11-24

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Application raterate = q ÷ (Se × Sl)1.6 L/h ÷ (0.4 × 1.2 m²) = 3.333 mm/h
    2. Gross depthnet ÷ efficiency5 ÷ 0.9 = 5.556 mm
    3. Run timegross depth ÷ rate5.556 ÷ 3.333 = 1.667 h
    4. Emitters and system flowarea ÷ (Se × Sl); × q10,000 ÷ 0.48 = 20,833 emitters; × 1.6 L/h = 33.33 m³/h
    5. Zonessystem flow ÷ pump capacity, rounded up33.33 ÷ 25 → 2 zones; all zones take 3.333 h

    Average rate and wetted area

    The rate here is averaged over the whole field. Under each emitter the soil is wetted much faster, which is why drip suits low-infiltration soils. For widely spaced trees, calculate the water each tree needs in litres per day instead and divide by the emitter flow and number of emitters per tree; the result is the same if the depth is based on the full area. Pressure-compensating emitters keep the flow close to the rated value across the field; ordinary emitters vary with pressure.

    Assumptions and limits

    • Emitters deliver their rated flow (pressure within the compensating range).
    • Zones are equal in size and run one after another.

    References

    • Keller, J. and Bliesner, R. D., Sprinkle and Trickle Irrigation, Van Nostrand Reinhold, 1990.
    • Vermeiren, L. and Jobling, G. A., Localized Irrigation: Design, Installation, Operation, Evaluation, FAO Irrigation and Drainage Paper 36, FAO, Rome, 1980.

    Questions

    How long should I run 1.6 L/h emitters at 40 cm on 1.2 m rows to apply 5 mm?
    The rate is 3.33 mm/h, so 5 mm net at 90% efficiency (5.56 mm gross) takes 1.67 hours, about 1 hour 40 minutes.
    How many emitters does a hectare need at that spacing?
    20,833 emitters drawing 33.3 m³/h in total, so a 25 m³/h pump must run two zones.

    Results depend on the figures you enter and on the assumptions listed above; field, animal and product conditions vary. Read the disclaimer.