Where the energy goes
Every 10 m of head (about 1 bar or 14.5 psi) costs about 2.7 kWh per megalitre of water at 100% efficiency, so a pump that is 63% efficient overall uses about 4.3 kWh per megalitre per 10 m. Reducing operating pressure (low-pressure sprinkler packages), cutting friction with larger pipes and keeping the pump near its best efficiency point all save energy; a pump test shows the actual efficiency. For a diesel pump, multiply the shaft energy by the engine's fuel consumption per kWh.
Assumptions and limits
- Water at 1,000 kg/m³; constant flow and head over the season.
- Electricity price is the average including demand and fixed charges if you want an all-in cost.
References
- Keller, J. and Bliesner, R. D., Sprinkle and Trickle Irrigation, Van Nostrand Reinhold, 1990.
- USDA Natural Resources Conservation Service, National Engineering Handbook, Part 623, Chapter 8: Irrigation Pumping Plants.
Questions
- What does it cost to pump 400 mm onto 20 ha?
- With 20 m lift, 8 m friction and 250 kPa at the field (53.5 m TDH) at 50 m³/h, the pump draws 11.6 kW, uses 231 kWh per megalitre and runs 1,600 hours: 18,504 kWh, or 2,776 at 0.15 per kWh.
- How many kWh does it take to pump an acre-foot?
- About 1.02 kWh per foot of head at 100% efficiency; divide by the overall pump and motor efficiency for the real figure.