Three ways to change the flux
The flux through a coil is Φ = BA·cosθ, so the EMF can come from changing the field, the area or the angle. A coil turning at angular speed ω in a steady field has a sinusoidal EMF with peak NBAω, which is how almost all electricity is generated. A rod of length L moving at speed v across a field B sweeps out area at the rate Lv, giving ε = BLv. Lenz’s law fixes the direction: the induced current always opposes the change that produced it.
Assumptions and limits
- Uniform field over the coil area.
- Average EMF for a field change over a finite time; the instantaneous value depends on how the field changes.
- Coil self-inductance neglected when finding the load current.
References
- Halliday, D., Resnick, R. and Walker, J., Fundamentals of Physics, 12th ed., Wiley, 2021, chapter on induction and inductance.
- Griffiths, D. J., Introduction to Electrodynamics, 4th ed., Cambridge University Press, 2017, chapter on electrodynamics.
Questions
- What EMF is induced when the field through a 200-turn, 100 cm² coil rises from 0 to 0.5 T in 0.1 s?
- 10 V on average. Into a 10 Ω load that drives 1 A and delivers 10 W.
- What peak voltage does a 200-turn, 100 cm² coil give spinning at 3000 rpm in 0.2 T?
- 125.7 V peak (88.9 V RMS) at 50 Hz.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.