Finite coils are weaker than the ideal formula
B = μ₀nI is exact only for an infinitely long solenoid. On the axis of a real coil of length ℓ and diameter D the centre field is reduced by the factor ℓ/√(ℓ² + D²), and at each end it is close to half the centre value. The long-coil inductance formula overestimates short coils; Wheeler’s 1928 formula corrects for the end effect and is good to about 1 % for single-layer coils longer than 0.8 radius.
Assumptions and limits
- Closely wound single-layer coil with uniform current density.
- Field values are on the axis.
- Air core unless μr is entered; magnetic saturation of cores is not modelled.
References
- Griffiths, D. J., Introduction to Electrodynamics, 4th ed., Cambridge University Press, 2017, chapter on magnetostatics.
- Wheeler, H. A. (1928), Simple inductance formulas for radio coils, Proceedings of the IRE 16(10), 1398–1400.
Questions
- What field does a 500-turn, 200 mm long, 40 mm diameter coil give at 2 A?
- 6.16 mT at the centre, compared with 6.28 mT from the ideal formula. Its inductance is about 1.97 mH by the long-coil formula and 1.81 mH by Wheeler’s formula.
- How can I double the field?
- Double the current or the number of turns per metre. Doubling the turns in the same length also quadruples the inductance.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.