Pressure bulbs and the 2:1 method
Boussinesq solved for the stresses in an elastic half-space under a surface point load. Integrating his result over a uniformly loaded rectangle gives Newmark's influence factor for a point below a corner; any other point, such as the centre, follows by adding or subtracting rectangles. Under the centre of a square footing the added stress falls to about half the applied pressure at a depth of one footing width and to about a tenth at two widths, the familiar pressure bulb. The 2:1 method spreads the load at one horizontal to two vertical and gives an average stress over the spread area, a little lower than the centre value at shallow depth.
Assumptions and limits
- Linear elastic, homogeneous, isotropic, semi-infinite soil; flexible footing with uniform pressure.
- Stress increase only: add the existing overburden for total stress.
References
- Boussinesq, J., 1885, Application des potentiels à l'étude de l'équilibre et du mouvement des solides élastiques.
- Newmark, N. M., 1935, Simplified computation of vertical pressures in elastic foundations, University of Illinois Engineering Experiment Station Circular 24.
- Das, B. M., Principles of Geotechnical Engineering, stresses in a soil mass.
Questions
- What stress does the default footing add at 2 m depth?
- A 2 × 3 m footing with 150 kPa net pressure adds 64.2 kPa under its centre at 2 m depth (43 % of the pressure) and 29.0 kPa under a corner. The 2:1 method gives an average of 45 kPa over the spread area.
- What is the stress 2 m directly below a 500 kN point load?
- Δσ_z = 3P/(2πz²) = 59.7 kPa directly below the load.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.