How the beam shares load with the soil
The soil reaction is assumed proportional to the local deflection, p = k_s·δ. The solution of EI·δ⁗ + k·δ = 0 decays and oscillates with distance, and the characteristic length 1/λ = (4EI/k)^¼ sets how far the load spreads. A stiff beam on soft soil spreads the load over a long length with small pressures; a flexible beam on stiff soil concentrates it. Beyond about 3/(4λ) from a central load the deflection reverses sign, and by 2π/λ the effect has died out, which is why a beam longer than that behaves as if it were infinitely long.
Assumptions and limits
- Linear elastic beam with constant EI on a Winkler foundation; the soil can pull as well as push (check that no uplift occurs, or that the uplift is small).
- Beam long enough that the far ends do not affect the result (length shown in the results).
- Single point load; several loads on a long beam can be added by superposition.
References
- Hetényi, M., 1946, Beams on Elastic Foundation, University of Michigan Press.
- Bowles, J. E., Foundation Analysis and Design, beams on elastic foundations and the modulus of subgrade reaction.
- Young, W. C. and Budynas, R. G., Roark's Formulas for Stress and Strain, beams on elastic foundations.
Questions
- What are the results for the default grade beam?
- A 600 × 600 mm concrete beam on soil with k_s = 30 MN/m³ has 1/λ = 2.91 m. A 500 kN load far from the ends deflects it 4.77 mm, causes a moment of 364 kN·m under the load and a peak soil pressure of 143 kPa.
- What changes if the load is at the end of the beam?
- The deflection quadruples to 19.1 mm, the soil pressure to 572 kPa, and the largest moment becomes 470 kN·m at 2.29 m from the end, hogging rather than sagging.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.