Adding PWHT to the original temper
A quenched and tempered steel that is later stress relieved receives extra tempering. Convert the PWHT to an equivalent time at the original tempering temperature, add it to the original time and recalculate P. If the total exceeds what the material specification allows, strength may drop below the minimum.
The constant C
C is often taken as 20. Grange and Baughman related it to carbon content as C = 21.3 − 5.8 × %C, which gives about 19 for a 0.4% carbon steel.
Assumptions and limits
- Temperature in kelvin and time in hours inside the formula.
- Below the lower critical temperature, Ac1.
References
- Hollomon, J. H. and Jaffe, L. D., Time-temperature relations in tempering steel, Trans. AIME, 1945.
- Grange, R. A. and Baughman, R. W., Hardness of tempered martensite in carbon and low alloy steels, 1956.
Questions
- Can I temper above Ac1 to save time?
- No. Above Ac1 austenite starts to form and the parameter no longer applies. Check the Ac1 of your steel.
- Is P the same for every steel?
- The formula is general, but the hardness reached for a given P depends on the steel. Use it to compare treatments of the same material.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.