Natural Convection Heat Transfer Coefficient Calculator

Free or natural convection is the heat carried away by air that rises as it warms against a surface. This calculator gives the coefficient for walls, panels, enclosures, pipes and tank tops in still air, using well-tested correlations for each shape.

Inputs

Results

Convection coefficient
4.991
Convective heat transfer
199.7
Rayleigh number
385,064,367
Nusselt number
91.59
Boundary layer
Laminar (Ra < 10⁹)

    RefENG-HT-006
    MethodNu = f(Ra, Pr) with air properties at the film temperature
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Air properties at film temperatureT_f = 40 °C: k = 0.02725 W/m·K, ν = 1.692e-5 m²/s, Pr = 0.7042
    2. Rayleigh numberRa = gβΔT·L³/(να), β = 1/T_fRa = 3.851e+8
    3. Nusselt numberNu = {0.825 + 0.387Ra^(1/6)/[1+(0.492/Pr)^(9/16)]^(8/27)}²Nu = 91.59
    4. Coefficienth = Nu·k/Lh = 4.991 W/m²·K

    Typical values

    Natural convection in air is weak: usually 2 to 10 W/m²·K. Radiation from the same surface is often of similar size, so add it separately with the radiation calculator when the surface is not bright metal.

    Assumptions and limits

    • Air at atmospheric pressure, quiescent surroundings.
    • Isothermal surface.
    • Properties evaluated at the film temperature.

    References

    • Churchill, S. W. and Chu, H. H. S., 1975, correlations for free convection from vertical plates and horizontal cylinders.
    • Lloyd, J. R. and Moran, W. R., 1974, horizontal plates.
    • Incropera, F. P. et al., Fundamentals of Heat and Mass Transfer, chapter 9.

    Questions

    What is the natural convection coefficient for a warm wall?
    For a 0.5 m high plate at 60 °C in 20 °C air, about 5.0 W/m²·K.
    What characteristic length should I use for a horizontal plate?
    Area divided by perimeter. For a square of side a, that is a/4.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.