Using it for buildings and equipment
For building fabric, the default surface coefficients follow ISO 6946. For ovens, furnaces and ducts, replace them with process film coefficients and use conductivities at the mean temperature of each layer. Thermal bridges such as studs, ties and fixings are ignored, so real U-values are usually somewhat higher.
Assumptions and limits
- One-dimensional steady conduction.
- Constant conductivity in each layer.
- No thermal bridging, air gaps or moisture.
References
- ISO 6946, Building components and elements: thermal resistance and thermal transmittance.
- Incropera, F. P. et al., Fundamentals of Heat and Mass Transfer, chapter 3.
Questions
- What is a good wall U-value?
- New external walls in Europe typically target 0.15 to 0.30 W/m²·K. The default wall here comes out at about 0.31 W/m²·K.
- What is the difference between U-value and R-value?
- R-value is the total thermal resistance; U-value is its reciprocal. Higher R or lower U means better insulation.