What sets the rate
The rate is proportional to sunlight and inversely proportional to the allowed temperature rise: halving the rise doubles the fans. A transpiring crop uses a large share of the energy to evaporate water, which is why an empty house overheats much more than a full one. Air is thinner at altitude and on hot days, so more volume is needed. A common rule of thumb is about one air change per minute in summer; evaporative pads, shading and fogging reduce the rate needed.
Assumptions and limits
- Steady state at peak radiation; heat stored in the structure and soil is ignored.
- Outside air enters at the outside temperature; the rise is measured across the house.
References
- ASABE EP406, Heating, Ventilating and Cooling Greenhouses, American Society of Agricultural and Biological Engineers.
- Hellickson, M. A. and Walker, J. N. (eds), Ventilation of Agricultural Structures, ASAE Monograph 6, 1983.
- Nelson, P. V., Greenhouse Operation and Management, 7th ed., Pearson, 2012.
Questions
- How much ventilation does an 800 m² greenhouse need at 800 W/m²?
- With 70% transmission, half the energy used by the crop and a 4 °C rise at 30 °C outside, about 47.8 m³/s (172,000 m³/h): 0.9 air changes a minute in a 3,200 m³ house, or five 35,000 m³/h fans.
- Why does an empty greenhouse need more ventilation?
- Without a crop transpiring, almost all the absorbed sunlight heats the air, so roughly twice the airflow is needed for the same rise.