Torsion of Thin-Walled Sections Calculator (Open and Closed)

How a thin-walled member resists twisting depends on whether its cross-section is closed, like a tube or box, or open, like an I-beam or channel. This calculator gives the torsion constant, maximum shear stress, shear flow and angle of twist for both kinds, so you can see why a closed box can be hundreds of times stiffer in torsion than an open section of similar weight.

Inputs

Results

Maximum shear stress, τ_max
43.73
Torsion constant, J
1,444
Angle of twist over the length
1.546
Torsional rigidity, GJ
1,112
Shear flow (closed sections), q = T/(2A_m)
275.5
Area enclosed by the wall centreline, A_m
18,150
Thick-wall check (round tubes): τ from T·r/J_polar
0

    RefENG-STR-025
    MethodClosed: τ = T/(2A_m·t), J = 4A_m²/∮ds/t; open: J = Σbt³/3, τ = T·t_max/J; θ = TL/(GJ)
    UnitsSI
    Date2026-11-24

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Bredt-Batho (closed thin-walled)A_m = (B − t_w)(H − t_f); ∮ds/t = 2(B − t_w)/t_f + 2(H − t_f)/t_w; J = 4A_m²/∮ds/tA_m = 18,150 mm²; ∮ds/t = 91.24; J = 1,444 cm⁴
    2. Shear flow and stressq = T/(2A_m); τ = q/t_minq = 275.5 N/mm; τ = 43.73 MPa
    3. Angle of twistθ = TL/(GJ)θ = 0.02698 rad = 1.546°

    Closed sections: Bredt-Batho

    In a closed tube the torque is carried by a constant shear flow q = T/(2A_m) circulating around the wall, where A_m is the area enclosed by the wall centreline. The stress is q divided by the local thickness, so it is highest where the wall is thinnest. The torsion constant J = 4A_m²/∮ds/t grows with the square of the enclosed area.

    Open sections: Saint-Venant

    An open section carries torque only by shear circulating within the thickness of each plate, giving J = Σbt³/3. Because thickness is cubed, open sections are very flexible in torsion: slitting a tube along its length reduces its stiffness by a factor of hundreds. Real I-beams and channels with restrained ends also resist torsion by warping, which this simple method does not include.

    Assumptions and limits

    • Thin walls (t much less than the other dimensions); linear elastic; uniform torque along the member.
    • Closed sections: single cell. Open sections: free warping (no warping restraint).
    • Plate lengths measured along the wall centreline.

    References

    • Megson, T. H. G., Structural and Stress Analysis, torsion of thin-walled sections.
    • Young, W. C. and Budynas, R. G., Roark's Formulas for Stress and Strain, torsion table.
    • Timoshenko, S. P. and Goodier, J. N., Theory of Elasticity.

    Questions

    What is the torsional stress in the default box section?
    A 200 × 100 × 6.3 mm box under 10 kN·m has an enclosed centreline area of 18,150 mm², a shear flow of 275.5 N/mm and a shear stress of 43.7 MPa. Its torsion constant is 1,444 cm⁴ and it twists 1.55° over 3 m.
    How much weaker is an open section?
    An IPE 300 modelled as three plates has J of about 15.7 cm⁴, against 1,444 cm⁴ for the default box. Under the same 10 kN·m its Saint-Venant shear stress would be about 680 MPa, far beyond yield, even though the IPE 300 is the heavier section. Open sections should not carry significant torque without warping restraint.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.