Dead Load Calculator (Slabs, Floors, Walls and Finishes)

Dead load is the permanent weight of the structure and everything fixed to it. This calculator adds up a floor or roof build-up layer by layer from thickness and unit weight, adds an allowance for ceilings and services, and turns the result into the line load on a supporting beam, including any wall built on it.

Inputs

Advanced options (5)

Results

Total dead load on the floor or roof
6.98
Of which build-up layers
6.48
Line load on the beam from the floor
20.94
Line load from the wall
6.555
Total dead line load on the beam
27.5
  • Unit weights are typical rounded values. Use manufacturers' data and the values in your loading code, and add the self weight of the beam itself.

RefENG-STR-032
MethodArea load = Σ(thickness × unit weight) + allowances; line load = area load × tributary width + wall height × thickness × unit weight
UnitsSI
Date2026-11-24

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Build-up layersq = Σ t_i·γ_i200 mm × 25 = 5 kPa + 50 mm × 22 = 1.1 kPa + 10 mm × 20 = 0.2 kPa + 15 mm × 12 = 0.18 kPa = 6.48 kPa
  2. Add allowancesq = 6.48 + 0.5 = 6.98 kPa (145.8 psf)
  3. Line load on the beamw = q × tributary width + wall height × thickness × γ6.98 × 3 + 3 × 0.115 × 19 = 20.94 + 6.555 = 27.5 kN/m

Dead load by layer

LayerMaterialThickness (mm)(in)Unit weight (kN/m³)(lbf/ft³)Load (kPa)(psf)
1Reinforced concrete, normal weight2007.87425159.15104.4
2Cement-sand screed501.969221401.122.97
3Ceramic tiles with adhesive100.393720127.30.24.177
4Gypsum plaster150.59061276.390.183.759
–Allowance––––0.510.44

From layers to beam loads

Each layer contributes its thickness times its unit weight: a 200 mm reinforced concrete slab at 25 kN/m³ weighs 5 kPa. A beam carries the floor from half the span on each side, its tributary width, so the area load times that width gives a line load in kN/m. A masonry wall standing on the beam adds its height times its thickness times its unit weight. Imposed (live) loads, partitions allowances and load factors come from your loading code and are added separately.

Assumptions and limits

  • Uniform layers over the whole area; tributary width taken as half the span each side.
  • Typical unit weights; actual product densities vary, especially for blocks, boards and insulation.
  • Wall load uniform along the beam, without openings.

References

  • EN 1991-1-1, Eurocode 1: Densities, self-weight and imposed loads for buildings (Annex A gives nominal densities).
  • ASCE/SEI 7, Minimum Design Loads, commentary tables of material weights.
  • Manufacturers' product data sheets for proprietary materials.

Questions

What is the dead load of the default floor?
A 200 mm RC slab (5 kPa), 50 mm screed (1.1 kPa), 10 mm tiles (0.2 kPa) and a 15 mm plaster ceiling (0.18 kPa), plus 0.5 kPa for services, total 6.98 kPa, or about 146 psf.
What line load does that put on a beam?
With a 3 m tributary width the floor gives 20.9 kN/m, and a 3 m high, 115 mm brick wall on the beam adds 6.6 kN/m, for 27.5 kN/m before the beam's own weight.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.