Built-Up and Composite Section Calculator (Parallel Axis Theorem)

Plate girders, beams with welded cover plates and composite sections are built from simple rectangles. This calculator stacks up to five rectangular parts, finds the neutral axis and the second moment of area with the parallel axis theorem, and gives the section moduli and the shear flow that the welds or bolts at each joint must carry.

Inputs

Advanced options (5)

Results

Second moment of area about the neutral axis, I
273,785
Neutral axis height above the datum
358.2
Area (actual)
23,350
Transformed area, ΣnA
23,350
Section modulus, top fibre
5,624
Section modulus, bottom fibre
7,643
Radius of gyration about the neutral axis
342.4
Second moment of area about the vertical centreline
11,548
First moment of area above the neutral axis, Q
3,691
Shear stress at the neutral axis
33.71
Largest shear flow at a joint between parts
331.5

    RefENG-STR-019
    MethodParallel axis theorem I = Σ(I_own + A·d²) on the transformed section; shear flow q = VQ/I
    UnitsSI
    Date2026-11-24

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Neutral axisȳ = Σ(nA·y_c) / Σ(nA)ΣnA = 23,350 mm²; ȳ = 358.2 mm above the datum
    2. Parallel axis theoremI = Σ(n·bh³/12 + nA·d²), d = y_c − ȳpart 1: 45.57 + 104,580; part 2: 51,200 + 4,282; part 3: 16.67 + 113,661 → I = 273,785 cm⁴
    3. Section moduliZ = I / distance to the extreme fibreZ_top = 5,624 cm³; Z_bot = 7,643 cm³
    4. Shear flow at each jointq = V·Q/I, Q = first moment of the area beyond the jointpart 1: 331.5 N/mm; part 3: 261.2 N/mm

    Contribution of each part (transformed areas)

    Partb × h (mm)y_c (mm)nA (mm²)d (mm)I_own + nA·d² (cm⁴)Shear flow at inner face (N/mm)(kip/in)
    1350 × 2512.58,750-345.7104,626331.51.893
    212 × 8004259,60066.7855,482404.5 at NA2.31
    3250 × 208355,000476.8113,678261.21.492

    Parallel axis theorem

    Each part contributes its own second moment bh³/12 about its centroid plus its area times the square of the distance to the neutral axis of the whole section, I = Σ(I_own + A·d²). Flanges far from the neutral axis contribute almost entirely through the A·d² term, which is why deep girders are so efficient. Parts are assumed to be centred on a common vertical axis, as in plate girders, tees and cover-plated beams.

    Shear flow and composite parts

    The connection between a flange or cover plate and the rest of the section carries a longitudinal shear flow q = VQ/I, where Q is the first moment of the part about the neutral axis. Divide by the number of weld lines or multiply by the fastener spacing to size the connection. For composite sections, enter each part's modular ratio n = E/E_ref; areas and stiffness are then transformed into the reference material.

    Assumptions and limits

    • Rectangular parts centred on a common vertical axis and fully connected (plane sections remain plane).
    • Linear elastic; bending about the horizontal axis.
    • Parts must not overlap.

    References

    • Gere, J. M. and Goodno, B. J., Mechanics of Materials, built-up beams and shear flow.
    • Hibbeler, R. C., Mechanics of Materials, parallel axis theorem and composite beams.
    • Salmon, C. G., Johnson, J. E. and Malhas, F. A., Steel Structures: Design and Behavior, plate girders.

    Questions

    What are the properties of the default plate girder?
    With a 350 × 25 mm bottom flange, an 800 × 12 mm web and a 250 × 20 mm top flange, the neutral axis is 358 mm above the underside and I = 273,800 cm⁴. Under 300 kN of shear, the joint between the bottom flange and the web carries 331 N/mm in total (166 N/mm per weld with a weld each side), and the top flange joint 261 N/mm.
    Why is the neutral axis below mid-depth?
    The bottom flange has more area than the top flange, so the centroid moves towards it. The top fibre is then further from the neutral axis and has the smaller section modulus.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.