Sign convention
Moments are reported in the usual moment distribution convention: clockwise moments acting on the member ends are positive. A downward load therefore gives a negative FEM_AB and a positive FEM_BA of equal size for symmetric loads, and both are hogging moments in the beam. If you prefer magnitudes, read FEM_AB as hogging when negative and FEM_BA as hogging when positive.
How distributed loads are handled
Each slice of a distributed load acts as a small point load, so its fixed-end moments follow from integrating Pab²/L² and Pa²b/L² along the loaded length. For a linearly varying load the integrand is a fourth-degree polynomial, which three-point Gauss integration evaluates exactly. This reproduces the textbook results: wL²/12 for a full uniform load and wL²/30 and wL²/20 for a triangle rising from A to B.
Assumptions and limits
- Prismatic member (constant EI) with both ends fully fixed against rotation and translation.
- Linear elastic behaviour; loads act transverse to the member.
References
- Hibbeler, R. C., Structural Analysis, fixed-end moment table and moment distribution.
- Cross, H., 1930, Analysis of continuous frames by distributing fixed-end moments, Proceedings of the ASCE.
- McCormac, J. C., Structural Analysis: Using Classical and Matrix Methods.
Questions
- What are the fixed-end moments for the default loads?
- For a 6 m span with 10 kN/m over the whole span and 30 kN at 2 m from A, FEM_AB = −56.67 kN·m and FEM_BA = +43.33 kN·m. With B pinned, the moment at A becomes −78.33 kN·m.
- What is the fixed-end moment for a point load at midspan?
- PL/8 at each end, hogging. For a full uniform load it is wL²/12 at each end, and the moment at midspan is wL²/24.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.