Beam Natural Frequency and Floor Vibration Calculator

Every beam has natural frequencies at which it vibrates freely. If footsteps, machines or rhythmic activity excite one of them, the floor can bounce noticeably. This calculator finds the first two natural frequencies of a beam from its stiffness, span and mass, adds a concentrated mass if needed, and screens the result against a minimum frequency.

Inputs

Results

Fundamental natural frequency, f₁
7.9
Second mode frequency, f₂ (beam mass only)
31.6
f₁ of the beam without the point mass
7.9
Period of the fundamental mode
0.1266
Static deflection under the vibrating load
5.049
Frequency check
OK: 7.9 Hz ≥ 3 Hz
  • A frequency screen is not a full vibration assessment. For sensitive floors, check response (acceleration or response factor) using a recognised guide.

RefENG-STR-017
Methodf_n = (λ_nL)²/(2π)·√(EI/(mL⁴)); point mass combined by Dunkerley
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Mass per unit lengthm = w/gm = 5 kN/m ÷ 9.807 = 509.9 kg/m
  2. Natural frequencies of the beamf_n = (λ_nL)²/(2π)·√(EI/(mL⁴)); (λL)² = 9.8696 and 39.478EI = 16,712 kN·m²; f₁ = 7.9 Hz; f₂ = 31.6 Hz
  3. Check with the static deflectionδ = 0.01302·wL⁴/EI; f ≈ 17.8/√δ(mm)δ = 5.049 mm; 17.8/√5.049 = 7.9 Hz

Formula and the 18/√δ shortcut

For a uniform beam, f = (λL)²/(2π)·√(EI/(mL⁴)), where (λL)² is π² for a simply supported beam, 3.516 for a cantilever, 22.37 for a fixed-ended beam and 15.42 for a propped cantilever. Because the static deflection δ under the same mass also depends on mL⁴/EI, the fundamental frequency of a simply supported beam is about 18/√δ with δ in millimetres. The other support cases give 18 to 20 instead of 18.

Floor vibration screening

Walking pace is roughly 1.6 to 2.4 steps per second, and its harmonics reach higher. A floor whose fundamental frequency sits near one of them can build up a resonant response. Design guides for steel and composite floors, such as AISC Design Guide 11 and SCI P354, assess response rather than frequency alone; a minimum of about 3 Hz is a common first screen, and floors above about 9 to 10 Hz are treated as high-frequency floors. Use the vibrating mass, not the factored design load: permanent load plus a small share of imposed load.

Assumptions and limits

  • Uniform Euler-Bernoulli beam; shear deformation and rotary inertia ignored (good when span/depth exceeds about 10).
  • Ideal supports; the point mass is combined with the beam by Dunkerley's method, which slightly underestimates the frequency.

References

  • Blevins, R. D., Formulas for Natural Frequency and Mode Shape.
  • Murray, T. M., Allen, D. E., Ungar, E. E. and Davis, D. B., AISC Design Guide 11, Vibrations of Steel-Framed Structural Systems Due to Human Activity.
  • Smith, A. L., Hicks, S. J. and Devine, P. J., SCI P354, Design of Floors for Vibration: A New Approach.

Questions

What is the natural frequency of the default beam?
An IPE 300 spanning 6 m, simply supported, with a 5 kN/m vibrating load has a fundamental frequency of 7.9 Hz and a second mode at 31.6 Hz. Its static deflection under that load is 5.05 mm, and 17.75/√5.05 gives the same 7.9 Hz.
How does adding a point mass change the frequency?
A 500 kg mass at midspan of the default beam lowers the fundamental frequency from 7.9 Hz to about 6.85 Hz (Dunkerley estimate).

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.