Formula and the 18/√δ shortcut
For a uniform beam, f = (λL)²/(2π)·√(EI/(mL⁴)), where (λL)² is π² for a simply supported beam, 3.516 for a cantilever, 22.37 for a fixed-ended beam and 15.42 for a propped cantilever. Because the static deflection δ under the same mass also depends on mL⁴/EI, the fundamental frequency of a simply supported beam is about 18/√δ with δ in millimetres. The other support cases give 18 to 20 instead of 18.
Floor vibration screening
Walking pace is roughly 1.6 to 2.4 steps per second, and its harmonics reach higher. A floor whose fundamental frequency sits near one of them can build up a resonant response. Design guides for steel and composite floors, such as AISC Design Guide 11 and SCI P354, assess response rather than frequency alone; a minimum of about 3 Hz is a common first screen, and floors above about 9 to 10 Hz are treated as high-frequency floors. Use the vibrating mass, not the factored design load: permanent load plus a small share of imposed load.
Assumptions and limits
- Uniform Euler-Bernoulli beam; shear deformation and rotary inertia ignored (good when span/depth exceeds about 10).
- Ideal supports; the point mass is combined with the beam by Dunkerley's method, which slightly underestimates the frequency.
References
- Blevins, R. D., Formulas for Natural Frequency and Mode Shape.
- Murray, T. M., Allen, D. E., Ungar, E. E. and Davis, D. B., AISC Design Guide 11, Vibrations of Steel-Framed Structural Systems Due to Human Activity.
- Smith, A. L., Hicks, S. J. and Devine, P. J., SCI P354, Design of Floors for Vibration: A New Approach.
Questions
- What is the natural frequency of the default beam?
- An IPE 300 spanning 6 m, simply supported, with a 5 kN/m vibrating load has a fundamental frequency of 7.9 Hz and a second mode at 31.6 Hz. Its static deflection under that load is 5.05 mm, and 17.75/√5.05 gives the same 7.9 Hz.
- How does adding a point mass change the frequency?
- A 500 kg mass at midspan of the default beam lowers the fundamental frequency from 7.9 Hz to about 6.85 Hz (Dunkerley estimate).
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.