Reactor Conversion Calculator (CSTR and PFR, First Order)

For the same volume, a plug flow reactor gives higher conversion than a single stirred tank, because a stirred tank runs entirely at the low outlet concentration. This calculator compares the ideal reactor types for a first-order reaction and sizes the volume for a target conversion.

Inputs

%

Results

Conversion
66.67%
Damköhler number, kτ
2
Total volume for the target conversion
9
Conversion if plug flow
86.47
%
Conversion if a single CSTR
66.67
%

    RefENG-CHE-006
    MethodPFR X = 1 − e^(−kτ); CSTR X = kτ/(1 + kτ); N tanks X = 1 − (1 + kτ/N)^(−N)
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Space time and Damköhler numberτ = V/Q; Da = kττ = 20 min; Da = 2
    2. ConversionX = 66.67 %
    3. Volume for targetDa needed = 9; V = Da·Q/k = 9 m³

    Tanks in series

    Splitting a stirred tank volume into several tanks in series moves performance towards plug flow. Three or four tanks recover most of the difference, which is why continuous processes and treatment plants often use cascades.

    Assumptions and limits

    • Isothermal, constant-density, irreversible first-order reaction.
    • Ideal mixing (CSTR) or ideal plug flow; equal tank volumes in series.

    References

    • Levenspiel, O., Chemical Reaction Engineering, chapters 5 and 6.
    • Fogler, H. S., Elements of Chemical Reaction Engineering.

    Questions

    What conversion does a 2 m³ CSTR give with k = 0.1 per minute at 6 m³/h?
    kτ = 2, so 66.7 %; a plug flow reactor of the same size would reach 86.5 %.
    How much bigger must a CSTR be than a PFR for 90 % conversion?
    About 3.9 times (kτ of 9 against 2.30).

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.