Bubble Point and Dew Point Calculator (Binary, Raoult's Law)

A liquid mixture starts to boil at its bubble point and is fully vaporised at its dew point. This calculator finds both for an ideal two-component mixture at a given pressure, together with the composition of the first vapour formed, the basis of distillation and flash calculations.

Inputs

%

Results

Bubble point
92.11
Dew point
98.77
Vapour mole fraction of component 1 at the bubble point
71.36
%
Relative volatility at the bubble point
2.492
  • Raoult's law assumes an ideal solution. Mixtures such as ethanol-water are strongly non-ideal and form azeotropes; use activity coefficients for those.

RefENG-CHE-008
MethodBubble: Σxᵢ·Pᵢsat(T) = P; dew: Σzᵢ/Pᵢsat(T) = 1/P
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Bubble pointx₁P₁sat(T) + x₂P₂sat(T) = PT = 92.11 °C; P₁sat = 144.6 kPa, P₂sat = 58.03 kPa
  2. Vapour in equilibriumy₁ = x₁P₁sat/Py₁ = 0.7136
  3. Dew pointz₁/P₁sat + z₂/P₂sat = 1/PT = 98.77 °C

Relative volatility

The ratio of vapour pressures, α, measures how easily the two components separate. Values above about 1.5 separate readily by distillation; close to 1 needs many stages or another method.

Assumptions and limits

  • Ideal liquid (Raoult's law) and ideal gas vapour.
  • Antoine constants within their fitted ranges.

References

  • Smith, J. M., Van Ness, H. C. and Abbott, M. M., Introduction to Chemical Engineering Thermodynamics, chapter 10.
  • Seader, J. D. and Henley, E. J., Separation Process Principles.

Questions

What is the bubble point of 50/50 benzene-toluene at 1 atm?
About 92 °C, with a first vapour of about 71 % benzene; the dew point is about 99 °C.
Can I use this for ethanol and water?
Only roughly. That system is strongly non-ideal and forms an azeotrope at about 89 mol % ethanol.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.