Arrhenius Equation Calculator (Rate Constant and Activation Energy)

Reaction rates rise steeply with temperature, as the Arrhenius equation describes. This calculator predicts the rate at a new temperature from the activation energy, or finds the activation energy from rates measured at two temperatures, which is how accelerated ageing and shelf-life tests are interpreted.

Inputs

Results

Result
k₂ = 0.3252 per min (6.504 × k₁)
Rate constant at T₂
0.3252
Activation energy
60
Rate increase k₂/k₁
6.504
Q10 (rate factor per 10 K near T₁)
2.19

    RefENG-CHE-005
    Methodln(k₂/k₁) = (E_a/R)·(1/T₁ − 1/T₂)
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Arrhenius relationln(k₂/k₁) = (E_a/R)(1/T₁ − 1/T₂)ln(6.504) = 60,000/8.314 × (1/298.2 − 1/323.2)
    2. Q10Q10 = exp[(E_a/R)(1/T₁ − 1/(T₁ + 10))]Q10 = 2.193

    The "doubling every 10 °C" rule

    A Q10 of 2 corresponds to an activation energy of about 53 kJ/mol near room temperature. Many reactions fall between 40 and 100 kJ/mol, so the rule is only a rough guide.

    Assumptions and limits

    • Single rate-controlling step with constant activation energy over the range.

    References

    • Atkins, P. and de Paula, J., Physical Chemistry.
    • ASTM F1980, accelerated ageing of sterile medical device packages (Q10 method).

    Questions

    How much faster is a reaction with E_a = 60 kJ/mol at 50 °C than at 25 °C?
    About 6.5 times faster.
    What activation energy gives a Q10 of 2?
    About 53 kJ/mol at 25 °C.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.