Drying Water Removal Calculator (Dryer Water Load, Energy and Airflow)

Drying fruit, vegetables, grains or other foods means removing a known mass of water every hour. This calculator works out that water load from the moisture contents, the heat needed to evaporate it, the heat supply at your dryer's efficiency and the air flow needed to carry the moisture away.

Results are estimates. Follow local agronomy advice and product labels.

Inputs

%
%
%

Results

Water removed
777.8
Dried product output
222.2
Initial moisture, dry basis
4
Final moisture, dry basis
0.1111
Heat to evaporate the water
514.8
Heat input at the dryer efficiency
1,030
Dry air flow
25,926
Air volume at the inlet
25,609

    RefAGR-FPR-002
    MethodWater removed = F·(M₁ − M₂) ÷ (100 − M₂); heat = water × latent heat ÷ η; dry air = water ÷ (W_out − W_in)
    UnitsSI
    Date2026-11-24

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Water removedF × (M₁ − M₂) ÷ (1 − M₂)1,000 kg/h × (0.8 − 0.1) ÷ 0.9 = 777.8 kg/h
    2. Dry-basis moistureX = M ÷ (1 − M)X₁ = 4, X₂ = 0.1111 kg water per kg dry solids
    3. Heatwater × h_fg; ÷ efficiency777.8 kg/h × 2,383 kJ/kg = 514.8 kW; ÷ 0.5 = 1,030 kW
    4. Drying airwater ÷ (W_out − W_in); × specific volume777.8 ÷ 0.03 = 25,926 kg/h dry air; × 0.9878 m³/kg = 25,609 m³/h

    Wet and dry basis

    Food moisture is usually given on the wet basis (water as a percentage of the total mass); drying calculations are easier on the dry basis (water per kilogram of dry solids), because the dry solids pass through unchanged. Going from 80% to 10% wet basis means going from 4.0 to 0.11 kg of water per kg of solids: most of the water comes off. The air must pick up that water: the difference between the exhaust and inlet humidity ratios (from a psychrometric chart) sets the air flow.

    Assumptions and limits

    • Steady continuous operation; no product losses.
    • Ideal-gas air at atmospheric pressure for the volume flow.

    References

    • Fellows, P. J., Food Processing Technology: Principles and Practice, 4th ed., Woodhead Publishing, 2017 (dehydration).
    • Mujumdar, A. S. (ed.), Handbook of Industrial Drying, 4th ed., CRC Press, 2014.
    • ASHRAE Handbook — Fundamentals, chapter 1: Psychrometrics.

    Questions

    How much water does a dryer remove from 1,000 kg/h of product at 80% dried to 10%?
    778 kg/h, leaving 222 kg/h of product. Evaporating it takes about 515 kW, or 1,030 kW of heat at 50% dryer efficiency.
    How much air is needed?
    With the air picking up 30 g of water per kg (10 to 40 g/kg), about 25,900 kg/h of dry air, roughly 25,600 m³/h at 70 °C.

    Results depend on the figures you enter and on the assumptions listed above; field, animal and product conditions vary. Read the disclaimer.