Stack Emission Rate Calculator (Concentration to kg/h, Oxygen Correction)

Stack test results are reported as concentrations, but permits and inventories also need mass emission rates. This calculator converts a measured concentration and stack gas flow into grams per second, kilograms per hour and tonnes per year, and corrects the concentration to the reference oxygen level used in emission limits.

Estimates using the emission factors shown. Check the factor source and year for formal reporting.

Inputs

%
%
%

Results

Mass emission rate
2.554
Mass emission rate
0.7094
Annual emission
20.43
Flow at normal conditions, dry
17,027
Concentration at reference oxygen
207.7

    RefENV-AIR-004
    MethodQ_N,dry = Q_actual × (273.15/T) × (p/101.325) × (1 − H₂O); ṁ = C × Q_N,dry; C_ref = C × (21 − O₂,ref) ÷ (21 − O₂,meas)
    UnitsSI
    Date2026-11-24

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Normalise the flowQ × (273.15/T) × (p/101.325) × (1 − H₂O)30,000 m³/h × 0.6306 × 1 × 0.9 = 17,027 Nm³/h dry
    2. Mass emission rateC × Q_N,dry150 mg/Nm³ × 17,027 Nm³/h = 2.554 kg/h = 0.7094 g/s
    3. Annualrate × hours2.554 kg/h × 8,000 h = 20.43 t
    4. Oxygen correctionC_ref = C × (21 − O₂,ref) ÷ (21 − O₂,meas)150 × (21 − 3) ÷ (21 − 8) = 207.7 mg/Nm³

    Reference conditions

    Gas volume changes with temperature, pressure and moisture, so concentrations and flows are expressed at reference conditions: in the EU, 273.15 K, 101.3 kPa and dry gas, with oxygen corrected to a standard level so that diluting the flue gas with air cannot make emissions look lower. The mass rate does not depend on the oxygen correction: use the concentration and flow at the same conditions. US practice often uses 20 °C or 68 °F as standard temperature and F-factors to express emissions per unit of heat input.

    Assumptions and limits

    • Concentration measured on dry gas at 0 °C and 101.325 kPa; flow measured at actual conditions.
    • Oxygen measured on a dry basis.

    References

    • Directive 2010/75/EU on industrial emissions (integrated pollution prevention and control), Annexes V and VI (reference conditions and oxygen contents).
    • US EPA, 40 CFR Part 60, Appendix A, Method 19: Determination of sulfur dioxide removal efficiency and particulate matter, sulfur dioxide, and nitrogen oxide emission rates.

    Questions

    What is the NOx emission rate at 150 mg/Nm³ in 30,000 m³/h of flue gas at 160 °C with 10% moisture?
    The flow is 17,027 Nm³/h dry, so 2.55 kg/h (0.71 g/s), or 20.4 t over 8,000 hours.
    What is 150 mg/Nm³ at 8% O₂ corrected to 3% O₂?
    150 × 18 ÷ 13 = 208 mg/Nm³.

    Results depend on the figures and factors you enter and on the assumptions listed above. Use the factor set your reporting scheme requires. Read the disclaimer.