Motor Start-Up (Acceleration) Time Calculator

Large fans, conveyors and centrifuges take time to reach speed, and motors heat up quickly while they do. This calculator refers the load inertia and torque through the gearbox to the motor and finds the run-up time from the net accelerating torque.

Inputs

%

Results

Acceleration time
0.9832
Total inertia at the motor shaft
0.88
Net accelerating torque at the motor
136.8
Kinetic energy at full speed
10.29

    RefENG-MEC-011
    Methodt = J_total·ω/(T_motor − T_load/(i·η)); J_total = J_m + J_load/i²
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Inertia referred to the motorJ = J_m + J_load/i²J = 0.08 + 20/25 = 0.88 kg·m²
    2. Accelerating torqueT_a = T_m − T_load/(i·η)T_a = 136.8 N·m
    3. Timet = J·ω/T_at = 0.88 × 152.9 / 136.8 = 0.9832 s

    Why gearing helps

    Load inertia seen by the motor falls with the square of the gear ratio, so a 5:1 reduction makes a heavy load look 25 times lighter. That is why high-inertia loads are usually driven through reduction gearing.

    Assumptions and limits

    • Constant average torques over the run-up.
    • Rigid drive train; inertia of gears included in J_load or J_motor.

    References

    • IEC 60034-12, Starting performance of single-speed three-phase cage induction motors.
    • Boldea, I. and Nasar, S. A., The Induction Machine Handbook.

    Questions

    How long does the default drive take to start?
    About 1.0 s: 0.88 kg·m² at the motor shaft accelerated by about 137 N·m of net torque to 1460 rpm.
    What happens if acceleration takes too long?
    The motor draws starting current for longer than its thermal limit and can trip or overheat. Soft starters lengthen run-up further.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.