Why gearing helps
Load inertia seen by the motor falls with the square of the gear ratio, so a 5:1 reduction makes a heavy load look 25 times lighter. That is why high-inertia loads are usually driven through reduction gearing.
Assumptions and limits
- Constant average torques over the run-up.
- Rigid drive train; inertia of gears included in J_load or J_motor.
References
- IEC 60034-12, Starting performance of single-speed three-phase cage induction motors.
- Boldea, I. and Nasar, S. A., The Induction Machine Handbook.
Questions
- How long does the default drive take to start?
- About 1.0 s: 0.88 kg·m² at the motor shaft accelerated by about 137 N·m of net torque to 1460 rpm.
- What happens if acceleration takes too long?
- The motor draws starting current for longer than its thermal limit and can trip or overheat. Soft starters lengthen run-up further.