Lapse Rate and Atmospheric Stability Calculator

How quickly temperature falls with height decides whether a rising bubble of air keeps rising or sinks back. This calculator finds the environmental lapse rate from two temperature readings and compares it with the dry and moist adiabatic rates to tell you whether the atmosphere is stable, conditionally unstable or absolutely unstable.

Inputs

Advanced options (1)

Results

Environmental lapse rate
6
Stability
Conditionally unstable: unstable only for saturated (cloudy) air
Dry adiabatic lapse rate
9.768
Moist adiabatic lapse rate at the lower level
4.243
Temperature at the chosen height (same lapse rate)
2

    RefESS-MET-005
    MethodΓ = −ΔT/Δz; Γd = g/c_p; Γs from the AMS saturated-adiabatic formula
    UnitsSI
    Date2026-11-24

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Environmental lapse rateΓ = −(T₂ − T₁)/(z₂ − z₁)Γ = −(8 − 20) / (2,000 − 0) m = 6 K/km
    2. Dry adiabatic lapse rateΓd = g/c_pdΓd = 9.80665 / 1004 = 9.768 K/km
    3. Moist adiabatic lapse rateΓs = g(1 + L_v r_s/(R_d T))/(c_pd + L_v² r_s ε/(R_d T²))at 20 °C and 1,013 hPa: Γs = 4.243 K/km
    4. CompareΓ < Γs stable; Γs < Γ < Γd conditionally unstable; Γ > Γd absolutely unstableConditionally unstable: unstable only for saturated (cloudy) air

    Reading stability

    A rising parcel of dry air cools at about 9.8 K/km; saturated air cools more slowly, 4 to 7 K/km near the ground, because condensation releases latent heat. If the surrounding air cools more slowly than the moist rate, any lifted parcel ends up colder than its surroundings and sinks back: the air is stable. If the environment cools faster than the dry rate, the air is absolutely unstable. In between, cloudy air rises freely while clear air does not, which is the usual set-up for showers and thunderstorms.

    Assumptions and limits

    • Linear temperature change between the two levels.
    • Parcel theory: no mixing between the rising air and its surroundings.
    • Moist lapse rate evaluated at the lower level; it changes with temperature and pressure.

    References

    • American Meteorological Society, Glossary of Meteorology, entries for dry-adiabatic and saturation-adiabatic lapse rates.
    • Wallace, J. M. and Hobbs, P. V., Atmospheric Science: An Introductory Survey, 2nd ed., Academic Press, 2006, chapter on atmospheric thermodynamics.
    • Bolton, D. (1980), The computation of equivalent potential temperature, Monthly Weather Review 108, 1046–1053.

    Questions

    Is a fall from 20 °C at the ground to 8 °C at 2 km stable?
    That is 6 K/km, between the moist rate (4.24 K/km at 20 °C and 1013 hPa) and the dry rate (9.77 K/km), so the air is conditionally unstable.
    What does a negative lapse rate mean?
    Temperature rises with height, an inversion. It is very stable and traps smoke and pollution near the ground.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.