Electrolysis Calculator (Faraday’s Laws: Mass, Time, Current)

In electrolysis the amount of substance produced at an electrode is proportional to the charge passed. Faraday’s laws turn current and time into the mass of metal plated or gas evolved, or tell you how long, or at what current, to run a cell to get the mass you need.

Inputs

g/mol
%

Results

Result
2.371 g
Mass
2.371
Time
1
Current
2
Charge passed
7,200
Amount of product
37.31
Gas volume at STP (0 °C, 100 kPa), for gases
–

    RefCHM-ELC-003
    Methodm = I·t·M·η/(z·F)
    UnitsSI
    Date2026-11-24

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Faraday’s lawsm = I·t·M·η/(z·F)m = 2 A × 3,600 s × 63.55 g/mol × 1 / (2 × 96485.33) = 2.371 g
    2. Charge and amountQ = I·t, n = m/MQ = 7,200 C (0.07462 mol of electrons), n = 0.03731 mol

    Charge, electrons and mass

    One mole of electrons carries 96,485 C, the Faraday constant. Depositing a metal from an ion of charge z+ needs z moles of electrons per mole of metal, so m = ItM/(zF). Copper from Cu²⁺ therefore needs twice the charge per mole of silver from Ag⁺. Real cells lose some current to side reactions such as hydrogen evolution; the current efficiency η corrects for this and is often well below 100 % for chromium plating.

    Assumptions and limits

    • Constant current; efficiency applies uniformly.
    • Molar masses from CIAAW standard atomic weights; F from the exact 2019 SI constants.
    • Gas volumes for dry ideal gas at 0 °C and 100 kPa.

    References

    • Bard, A. J. and Faulkner, L. R., Electrochemical Methods: Fundamentals and Applications, 2nd ed., Wiley, 2001, chapter 1.
    • Faraday, M. (1834), Experimental researches in electricity, seventh series, Philosophical Transactions of the Royal Society of London 124, 77–122.

    Questions

    How much copper does 2.00 A deposit in 1 hour?
    2.371 g, from 7200 C of charge (0.07462 mol of electrons).
    How long does it take to plate 1.000 g of silver at 0.500 A?
    1789 s, just under 30 minutes, at 100 % efficiency.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.